(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling_res.mat --stripRoot --tempDir=temp_ThermofluidStream_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling_fmu --startTime=0 --stopTime=1000 --stepSize=0.4 --timeout=50 --tolerance=1e-06 ../ThermofluidStream_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1000.000000 - tolerance : 1e-06 - stepSize : 0.4 info: maximum step size for 'Tank_overfilling.root': 0.400000 info: Result file: ../ThermofluidStream_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling_res.mat (bufferSize=10) info: Variable Tank_overfilling.acceleration.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.boundaryFore1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.boundaryFore1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.boundaryFore1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.boundaryFore1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.checkValve.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.flowResistance.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.flowResistance2.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.flowResistance5.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source1.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source1.instanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1/Undirected/Boundaries/TankCuboid.mo:58:3-58:107:writable] | | | | The following assertion has been violated at time 0.903659 | | | | ((tank1.V_liquid <= tank1.V_ref)) --> "Trying to fit more liquid into tank than it holds" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1/Undirected/Boundaries/Internal/PartialTankUndirected.mo:232:5-235:36:writable] | | | | The following assertion has been violated at time 1.200000 | | | | ((checkValve.inlet.m_flow > tank1.m_flow_assert)) --> "Negative massflow at tank inlet" info: Final Statistics for 'Tank_overfilling.root': NumSteps = 2722 NumRhsEvals = 2846 NumLinSolvSetups = 159 NumNonlinSolvIters = 2845 NumNonlinSolvConvFails = 1 NumErrTestFails = 7 info: 2 warnings info: 0 errors