Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan_Qin.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.8203/0.8203, allocations: 153.8 MB / 172.7 MB, free: 4.863 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestFan_Qin",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestFan_Qin",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.0005293/0.0005293, allocations: 15.97 kB / 249.8 MB, free: 4.355 MB / 206.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1746/0.1751, allocations: 33.36 MB / 283.2 MB, free: 1.723 MB / 222.1 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin): time 1.763/1.938, allocations: 311.4 MB / 0.5806 GB, free: 16.95 MB / 478.1 MB Notification: Performance of NFInst.instExpressions: time 0.1597/2.098, allocations: 134.2 MB / 0.7117 GB, free: 10.75 MB / 0.5762 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0008212/2.098, allocations: 8 kB / 0.7117 GB, free: 10.74 MB / 0.5762 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/SourcePQ.mo:18:3-19:83:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/Sink.mo:15:3-17:16:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:52:3-54:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:55:3-56:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:59:3-60:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:57:3-59:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:60:3-62:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:27:3-28:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:29:3-30:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:52:3-53:83:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:56:3-57:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:58:3-60:16:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:57:3-59:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:60:3-62:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:27:3-28:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:29:3-30:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:24:3-26:24:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:27:3-28:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:30:3-32:17:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:48:3-50:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:51:3-52:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:53:3-55:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:56:3-57:83:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:10:3-12:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:13:3-15:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:10:3-12:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:13:3-15:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0006694/2.099, allocations: 227 kB / 0.7119 GB, free: 10.52 MB / 0.5762 GB Notification: Performance of NFTyping.typeBindings: time 0.001053/2.1, allocations: 491.4 kB / 0.7124 GB, free: 10.04 MB / 0.5762 GB Notification: Performance of NFTyping.typeClassSections: time 0.003611/2.104, allocations: 1.511 MB / 0.7138 GB, free: 8.527 MB / 0.5762 GB Notification: Performance of NFFlatten.flatten: time 0.002823/2.106, allocations: 2.356 MB / 0.7161 GB, free: 6.164 MB / 0.5762 GB Notification: Performance of NFFlatten.resolveConnections: time 0.001317/2.108, allocations: 1.015 MB / 0.7171 GB, free: 5.109 MB / 0.5762 GB Notification: Performance of NFEvalConstants.evaluate: time 0.000998/2.109, allocations: 0.8958 MB / 0.718 GB, free: 4.211 MB / 0.5762 GB Notification: Performance of NFSimplifyModel.simplify: time 0.001097/2.11, allocations: 0.9027 MB / 0.7189 GB, free: 3.305 MB / 0.5762 GB Notification: Performance of NFPackage.collectConstants: time 0.0003003/2.11, allocations: 244 kB / 0.7191 GB, free: 3.066 MB / 0.5762 GB Notification: Performance of NFFlatten.collectFunctions: time 0.00225/2.112, allocations: 1.109 MB / 0.7202 GB, free: 1.957 MB / 0.5762 GB Notification: Performance of NFScalarize.scalarize: time 0.0004528/2.113, allocations: 0.5025 MB / 0.7207 GB, free: 1.453 MB / 0.5762 GB Notification: Performance of NFVerifyModel.verify: time 0.0008802/2.114, allocations: 0.8715 MB / 0.7216 GB, free: 0.5781 MB / 0.5762 GB Notification: Performance of NFConvertDAE.convert: time 0.003396/2.117, allocations: 2.889 MB / 0.7244 GB, free: 13.68 MB / 0.5919 GB Notification: Performance of FrontEnd - DAE generated: time 3.677e-06/2.117, allocations: 4 kB / 0.7244 GB, free: 13.68 MB / 0.5919 GB Notification: Performance of FrontEnd: time 1.423e-06/2.117, allocations: 2.344 kB / 0.7244 GB, free: 13.68 MB / 0.5919 GB Notification: Performance of Transformations before backend: time 3.175e-05/2.117, allocations: 0 / 0.7244 GB, free: 13.68 MB / 0.5919 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 508 * Number of variables: 508 Notification: Performance of Generate backend data structure: time 0.00412/2.121, allocations: 2.208 MB / 0.7265 GB, free: 11.43 MB / 0.5919 GB Notification: Performance of prepare preOptimizeDAE: time 4.078e-05/2.121, allocations: 8.031 kB / 0.7265 GB, free: 11.42 MB / 0.5919 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.0003278/2.122, allocations: 279.1 kB / 0.7268 GB, free: 11.14 MB / 0.5919 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.0003438/2.122, allocations: 228.4 kB / 0.727 GB, free: 10.91 MB / 0.5919 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.001056/2.123, allocations: 0.671 MB / 0.7277 GB, free: 10.21 MB / 0.5919 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0001876/2.123, allocations: 203.4 kB / 0.7279 GB, free: 10 MB / 0.5919 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0004154/2.124, allocations: 219.9 kB / 0.7281 GB, free: 9.789 MB / 0.5919 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.003708/2.127, allocations: 2.427 MB / 0.7305 GB, free: 7.176 MB / 0.5919 GB Notification: Performance of preOpt findStateOrder (simulation): time 4.195e-05/2.127, allocations: 7.938 kB / 0.7305 GB, free: 7.168 MB / 0.5919 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0001551/2.128, allocations: 84 kB / 0.7305 GB, free: 7.086 MB / 0.5919 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 5.178e-05/2.128, allocations: 52 kB / 0.7306 GB, free: 7.035 MB / 0.5919 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.003588/2.131, allocations: 2.044 MB / 0.7326 GB, free: 4.988 MB / 0.5919 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.01088/2.142, allocations: 8.718 MB / 0.7411 GB, free: 12.04 MB / 0.6075 GB Notification: Performance of preOpt comSubExp (simulation): time 0.002182/2.144, allocations: 1.014 MB / 0.7421 GB, free: 11.01 MB / 0.6075 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.001306/2.146, allocations: 0.7529 MB / 0.7428 GB, free: 10.25 MB / 0.6075 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0005366/2.146, allocations: 188.8 kB / 0.743 GB, free: 10.07 MB / 0.6075 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.001443/2.148, allocations: 0.8318 MB / 0.7438 GB, free: 9.219 MB / 0.6075 GB Notification: Performance of pre-optimization done (n=128): time 3.186e-06/2.148, allocations: 0 / 0.7438 GB, free: 9.219 MB / 0.6075 GB Warning: Some equations could not be differentiated for following variables having attribute stateSelect=StateSelect.prefer. They will be treated as if they had stateSelect=StateSelect.default ======================================== 1: volume2S.T Please use -d=bltdump for more information. Notification: Performance of matching and sorting (n=213): time 0.1596/2.307, allocations: 31.81 MB / 0.7749 GB, free: 9.441 MB / 0.6387 GB " [Timeout remaining time 657] [Calling sys.exit(0), Time elapsed: 3.931250602938235] Failed to read output from testmodel.py, exit status != 0: 2.6494150180369616 2.660534959 0.540737432 Calling exit ...