(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_OpenHydraulics_OpenHydraulics_DevelopmentTests_ServoValveMeteringTest_fmu --startTime=0 --stopTime=100 --stepSize=0.04 --timeout=50 --tolerance=1e-06 ../OpenHydraulics_OpenHydraulics_DevelopmentTests_ServoValveMeteringTest.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : OpenHydraulics.DevelopmentTests.ServoValveMeteringTest (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 100.000000 - tolerance : 1e-06 - stepSize : 0.04 info: model doesn't contain any continuous state info: maximum step size for 'ServoValveMeteringTest.root': 0.040000 info: Result file: OpenHydraulics_OpenHydraulics_DevelopmentTests_ServoValveMeteringTest_res.mat (bufferSize=10) info: Parameter ServoValveMeteringTest.VR10.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter ServoValveMeteringTest.VR10.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter ServoValveMeteringTest.VR10.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter ServoValveMeteringTest.VR100.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter ServoValveMeteringTest.VR100.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter ServoValveMeteringTest.VR100.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter ServoValveMeteringTest.VR30.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter ServoValveMeteringTest.VR30.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter ServoValveMeteringTest.VR30.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable ServoValveMeteringTest.oil.oilName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'ServoValveMeteringTest.root': NumSteps = 2502 NumRhsEvals = 2503 NumLinSolvSetups = 127 NumNonlinSolvIters = 2502 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors