(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_fmu --startTime=0 --stopTime=10 --stepSize=0.004 --timeout=50 --tolerance=1e-08 ../OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : OpenHydraulics.DevelopmentTests.DirectionalValveTest (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 10.000000 - tolerance : 1e-08 - stepSize : 0.004 info: maximum step size for 'DirectionalValveTest.root': 0.004000 info: Result file: OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_res.mat (bufferSize=10) info: Variable DirectionalValveTest.oil.oilName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.A2T.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.A2T.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.A2T.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.B2T.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.B2T.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.B2T.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2A.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2A.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2A.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2B.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2B.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter DirectionalValveTest.valve4_3pos.P2B.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported warning: [fmi2Warning] DirectionalValveTest/logStatusWarning: The following assertion has been violated at time 0.000002 LOG_ASSERT | debug | Model error: Argument of sqrt((-restriction.dp) * constNeg) was -1.11759e-08 should be >= 0 error: [fmi2logger] [fmi2Error] DirectionalValveTest/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable valve4_3pos.j4.volumeClosed.compressible warning: [fmi2Warning] DirectionalValveTest/logStatusWarning: The following assertion has been violated at time 1.031805 LOG_ASSERT | debug | Model error: Argument of sqrt(restriction.dp * constPos) was -3.57628e-10 should be >= 0 error: [fmi2logger] [fmi2Error] DirectionalValveTest/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [completedIntegratorStep] fmi2_completedIntegratorStep failed for FMU "DirectionalValveTest.root.DirectionalValveTest" warning: Bad return code at time 1.031805 warning: [fmi2Warning] DirectionalValveTest/logStatusWarning: The following assertion has been violated at time 1.031805 LOG_ASSERT | debug | Model error: Argument of sqrt(restriction.dp * constPos) was -3.57628e-10 should be >= 0 error: [fmi2logger] [fmi2Error] DirectionalValveTest/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable valve4_3pos.j4.volumeClosed.compressible Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 266, in main handler(args.model, args) File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 140, in _runFMU fmu.simulate() File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 904, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: Final Statistics for 'DirectionalValveTest.root': NumSteps = 794 NumRhsEvals = 1305 NumLinSolvSetups = 103 NumNonlinSolvIters = 1304 NumNonlinSolvConvFails = 8 NumErrTestFails = 40 info: 6 warnings info: 6 errors