(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_fmu --startTime=0 --stopTime=100 --stepSize=0.04 --timeout=50 --tolerance=1e-06 ../OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : OpenHydraulics.Circuits.PressureCompensatedLoadSensing (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 100.000000 - tolerance : 1e-06 - stepSize : 0.04 info: maximum step size for 'PressureCompensatedLoadSensing.root': 0.040000 info: Result file: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_res.mat (bufferSize=10) info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionHead.cushionRestriction.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionHead.cushionRestriction.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionHead.cushionRestriction.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionHead.cushionTableBlock.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionHead.cushionTableBlock.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionHead.cushionTableBlock.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionHead.reliefValve.variableRestriction.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionHead.reliefValve.variableRestriction.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionHead.reliefValve.variableRestriction.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionRod.cushionRestriction.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionRod.cushionRestriction.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionRod.cushionRestriction.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionRod.cushionTableBlock.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionRod.cushionTableBlock.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionRod.cushionTableBlock.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionRod.reliefValve.variableRestriction.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionRod.reliefValve.variableRestriction.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.doubleActingCylinder.cushionRod.reliefValve.variableRestriction.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable PressureCompensatedLoadSensing.oil.oilName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.reliefValve.variableRestriction.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.reliefValve.variableRestriction.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.reliefValve.variableRestriction.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.A2T.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.A2T.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.A2T.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.B2T.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.B2T.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.B2T.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.P2A.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.P2A.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.P2A.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.P2B.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.P2B.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.P2B.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.checkT2A.variableRestriction.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.checkT2A.variableRestriction.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.checkT2A.variableRestriction.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.checkT2B.variableRestriction.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.checkT2B.variableRestriction.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.checkT2B.variableRestriction.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.reliefA2T.variableRestriction.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.reliefA2T.variableRestriction.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.reliefA2T.variableRestriction.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.reliefB2T.variableRestriction.MeteringTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.reliefB2T.variableRestriction.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter PressureCompensatedLoadSensing.valve4way3pos.reliefB2T.variableRestriction.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'PressureCompensatedLoadSensing.root': NumSteps = 263 NumRhsEvals = 488 NumLinSolvSetups = 43 NumNonlinSolvIters = 487 NumNonlinSolvConvFails = 11 NumErrTestFails = 9 info: 2 warnings info: 0 errors