(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_latest_Buildings_Templates_Plants_Controls_HeatPumps_Subsequences_Validation_AssertMinimumRuntime_fmu --startTime=0 --stopTime=100 --stepSize=0.04 --timeout=50 --tolerance=1e-06 ../Buildings_latest_Buildings_Templates_Plants_Controls_HeatPumps_Subsequences_Validation_AssertMinimumRuntime.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : Buildings.Templates.Plants.Controls.HeatPumps.Subsequences.Validation.AssertMinimumRuntime (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 100.000000 - tolerance : 1e-06 - stepSize : 0.04 info: model doesn't contain any continuous state info: maximum step size for 'AssertMinimumRuntime.root': 0.040000 info: Result file: Buildings_latest_Buildings_Templates_Plants_Controls_HeatPumps_Subsequences_Validation_AssertMinimumRuntime_res.mat (bufferSize=10) info: Variable AssertMinimumRuntime.assOffTim.assRunTim[1].message will not be stored in the result file, because the signal type is not supported info: Parameter AssertMinimumRuntime.assOffTim.message will not be stored in the result file, because the signal type is not supported info: Variable AssertMinimumRuntime.assRunTim.assRunTim[1].message will not be stored in the result file, because the signal type is not supported info: Variable AssertMinimumRuntime.assRunTim.assRunTim[2].message will not be stored in the result file, because the signal type is not supported info: Parameter AssertMinimumRuntime.assRunTim.message will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 10.000000 | | | | ((assRunTim.nor[2].y)) --> "HP minimum runtime is not met." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 10.000000 | | | | ((assRunTim.nor[1].y)) --> "HP minimum runtime is not met." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 30.000000 | | | | ((assOffTim.nor[1].y)) --> "HP minimum off-time is not met." info: Final Statistics for 'AssertMinimumRuntime.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors