(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_DecouplingMixing_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --timeout=50 --tolerance=1e-06 ../Buildings_13_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_DecouplingMixing.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DecouplingMixing (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-06 - stepSize : 34.56 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con1.pum.pumSpe.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con1.pum.pumSpe.heaDis.etaHyd, has value: -5.71093e-31" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con1.pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con1.pum.pumSpe.etaHyd, has value: -9.69271e-35" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((loa1.loa.coi.SHR >= 0.0 and loa1.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa1.loa.coi.SHR <= 1.0, has value: -1.84316e-27" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((loa.loa.coi.SHR >= 0.0 and loa.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa.loa.coi.SHR <= 1.0, has value: -9.08011e-27" info: maximum step size for 'DecouplingMixing.root': 34.560000 info: Result file: Buildings_13_Buildings_Fluid_HydronicConfigurations_ActiveNetworks_Examples_DecouplingMixing_res.mat (bufferSize=10) error: [doStepCVODE] CVode failed with flag = -1 warning: Bad return code at time 29175.385922 Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 266, in main handler(args.model, args) File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 140, in _runFMU fmu.simulate() File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 904, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: Final Statistics for 'DecouplingMixing.root': NumSteps = 1059 NumRhsEvals = 1636 NumLinSolvSetups = 87 NumNonlinSolvIters = 1635 NumNonlinSolvConvFails = 8 NumErrTestFails = 15 info: 3 warnings info: 1 errors