(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_VariableSpeed_fmu --startTime=0 --stopTime=2000 --stepSize=0.8 --timeout=50 --tolerance=1e-06 ../Buildings_13_Buildings_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_VariableSpeed.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : Buildings.Fluid.HeatPumps.Validation.ReciprocatingWaterToWater_VariableSpeed (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 2000.000000 - tolerance : 1e-06 - stepSize : 0.8 LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatPumps/Compressors/BaseClasses/PartialCompressor.mo:88:3-90:42:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((heaPum.com.port_a.T > 173.15 and heaPum.com.port_a.T < 345.25)) --> "Evaporating temperature must be above the minimum refrigerant temperature | | | | and below the critical temperature." error: [fmi2logger] [fmi2Error] ReciprocatingWaterToWater_VariableSpeed/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "ReciprocatingWaterToWater_VariableSpeed.root.ReciprocatingWaterToWater_VariableSpeed" error: [initialize] Initialization of system "ReciprocatingWaterToWater_VariableSpeed.root" failed Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 266, in main handler(args.model, args) File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 139, in _runFMU fmu.initialize() File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 885, in initialize raise RuntimeError(f"Failed to initialize model: {status}") RuntimeError: Failed to initialize model: Status.error info: 2 warnings info: 3 errors