(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Electrical_DC_Lines_Examples_DCLinesLinearized_fmu --startTime=0 --stopTime=4000 --stepSize=1.6 --timeout=50 --tolerance=1e-06 ../Buildings_13_Buildings_Electrical_DC_Lines_Examples_DCLinesLinearized.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : Buildings.Electrical.DC.Lines.Examples.DCLinesLinearized (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 4000.000000 - tolerance : 1e-06 - stepSize : 1.6 info: model doesn't contain any continuous state info: maximum step size for 'DCLinesLinearized.root': 1.600000 info: Result file: Buildings_13_Buildings_Electrical_DC_Lines_Examples_DCLinesLinearized_res.mat (bufferSize=10) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Electrical/Interfaces/Load.mo:79:3-79:117:writable] | | | | The following assertion has been violated at time 800.000000 | | | | ((varLoad5.y >= 0.0 and varLoad5.y <= 1.0000000001)) --> "The power load fraction P (input of the model) must be within [0,1]" error: [fmi2logger] [fmi2Error] DCLinesLinearized/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [completedIntegratorStep] fmi2_completedIntegratorStep failed for FMU "DCLinesLinearized.root.DCLinesLinearized" warning: Bad return code at time 800.000000 LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Electrical/Interfaces/Load.mo:79:3-79:117:writable] | | | | The following assertion has been violated at time 800.000000 | | | | ((varLoad5.y >= 0.0 and varLoad5.y <= 1.0000000001)) --> "The power load fraction P (input of the model) must be within [0,1]" error: [fmi2logger] [fmi2Error] DCLinesLinearized/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable load9.linearized Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 266, in main handler(args.model, args) File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 140, in _runFMU fmu.simulate() File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 904, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: Final Statistics for 'DCLinesLinearized.root': NumSteps = 129 NumRhsEvals = 130 NumLinSolvSetups = 11 NumNonlinSolvIters = 129 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 3 warnings info: 4 errors