(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Plants_Combined_Subsystems_Validation_CoolingTowerGroup_fmu --startTime=0 --stopTime=1000 --stepSize=0.4 --timeout=50 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Plants_Combined_Subsystems_Validation_CoolingTowerGroup.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : Buildings.DHC.Plants.Combined.Subsystems.Validation.CoolingTowerGroup (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1000.000000 - tolerance : 1e-06 - stepSize : 0.4 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((coo.datCooTow.PFan_Q_flow_nominal >= -0.1 and coo.datCooTow.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= coo.datCooTow.PFan_Q_flow_nominal <= 0.0, has value: 0.0144558" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((coo.coo.dat.PFan_Q_flow_nominal >= -0.1 and coo.coo.dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= coo.coo.dat.PFan_Q_flow_nominal <= 0.0, has value: 0.0144558" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((coo.coo.per.dat.PFan_Q_flow_nominal >= -0.1 and coo.coo.per.dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= coo.coo.per.dat.PFan_Q_flow_nominal <= 0.0, has value: 0.0144558" info: maximum step size for 'CoolingTowerGroup.root': 0.400000 info: Result file: Buildings_13_Buildings_DHC_Plants_Combined_Subsystems_Validation_CoolingTowerGroup_res.mat (bufferSize=10) info: Final Statistics for 'CoolingTowerGroup.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors