(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Controls_OBC_CDL_Integers_Validation_Stage_fmu --startTime=0 --stopTime=10 --stepSize=0.004 --timeout=50 --tolerance=1e-06 ../Buildings_13_Buildings_Controls_OBC_CDL_Integers_Validation_Stage.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : Buildings.Controls.OBC.CDL.Integers.Validation.Stage (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 10.000000 - tolerance : 1e-06 - stepSize : 0.004 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Integers/Stage.mo:26:3-31:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sta.y >= 1 and sta.y <= 4)) --> "Variable violating min/max constraint: 1 <= sta.y <= 4, has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Integers/Stage.mo:26:3-31:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zerHolTim.y >= 1 and zerHolTim.y <= 4)) --> "Variable violating min/max constraint: 1 <= zerHolTim.y <= 4, has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Integers/Stage.mo:26:3-31:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((sta1.y >= 1 and sta1.y <= 4)) --> "Variable violating min/max constraint: 1 <= sta1.y <= 4, has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Integers/Stage.mo:26:3-31:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((lesHolTim.y >= 1 and lesHolTim.y <= 4)) --> "Variable violating min/max constraint: 1 <= lesHolTim.y <= 4, has value: 0" info: model doesn't contain any continuous state info: maximum step size for 'Stage.root': 0.004000 info: Result file: Buildings_13_Buildings_Controls_OBC_CDL_Integers_Validation_Stage_res.mat (bufferSize=10) info: Final Statistics for 'Stage.root': NumSteps = 102 NumRhsEvals = 103 NumLinSolvSetups = 7 NumNonlinSolvIters = 102 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors