(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms_fmu --startTime=0 --stopTime=7200 --stepSize=2.88 --timeout=50 --tolerance=1e-06 ../Buildings_13_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Subsequences.Validation.Alarms (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 7200.000000 - tolerance : 1e-06 - stepSize : 2.88 info: model doesn't contain any continuous state info: maximum step size for 'Alarms.root': 2.880000 info: Result file: Buildings_13_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms_res.mat (bufferSize=10) info: Variable Alarms.ala.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes1.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes2.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes3.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes4.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes5.message will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 4350.000000 | | | | ((not ala.truDel5.y)) --> "Warning: the hot-duct damper is leaking." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 4350.000000 | | | | ((not ala.truDel3.y)) --> "Warning: the cold-duct damper is leaking." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 6225.000001 | | | | ((not ala.truDel4.y)) --> "Warning: hot-duct airflow sensor should be calibrated." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 6225.000001 | | | | ((not ala.truDel2.y)) --> "Warning: cold-duct airflow sensor should be calibrated." info: Final Statistics for 'Alarms.root': NumSteps = 343 NumRhsEvals = 344 NumLinSolvSetups = 21 NumNonlinSolvIters = 343 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors