/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Examples.DualFanDualDuct.ClosedLoop_res.mat --tempDir=temp_Buildings_11_Buildings_Examples_DualFanDualDuct_ClosedLoop_fmu --startTime=0 --stopTime=172800 --stepSize=69.12 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Examples_DualFanDualDuct_ClosedLoop.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Examples.DualFanDualDuct.ClosedLoop" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Examples.DualFanDualDuct.ClosedLoop" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Examples.DualFanDualDuct.ClosedLoop/model-i0fg9y5n" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Examples.DualFanDualDuct.ClosedLoop" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_11_Buildings_Examples_DualFanDualDuct_ClosedLoop.fmu - startTime: 0.000000 - stopTime: 172800.000000 - tolerance: 0.000001 - stepSize: 69.120000 LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Examples.DualFanDualDuct.ClosedLoop/674.fmutmp/sources/Buildings_11_Buildings_Examples_DualFanDualDuct_ClosedLoop_functions.c:13114: Invalid root: (0)^(-1.5) LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Examples.DualFanDualDuct.ClosedLoop/674.fmutmp/sources/Buildings_11_Buildings_Examples_DualFanDualDuct_ClosedLoop_functions.c:13114: Invalid root: (0)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Examples.DualFanDualDuct.ClosedLoop/674.fmutmp/sources/Buildings_11_Buildings_Examples_DualFanDualDuct_ClosedLoop_functions.c:13114: Invalid root: (0)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Examples.DualFanDualDuct.ClosedLoop/674.fmutmp/sources/Buildings_11_Buildings_Examples_DualFanDualDuct_ClosedLoop_functions.c:13114: Invalid root: (0)^(-1.5) LOG_ASSERT | debug | Solving non-linear system 5403 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | error | Failed to solve the initialization problem with global homotopy with equidistant step size. LOG_ASSERT | debug | Unable to solve initialization problem. error: [fmi2logger] [fmi2Error] Buildings_11_Buildings_Examples_DualFanDualDuct_ClosedLoop/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.Buildings_11_Buildings_Examples_DualFanDualDuct_ClosedLoop" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors