/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneVentilated" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneVentilated" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneVentilated/model-9t6yajs8" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Zones.Examples.SingleZoneVentilated" info: *** FMU Simulation Info *** - model: model (model exchange) - path: BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Airflow/Multizone/MediumColumn.mo:10:3-10:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zone.airpath[2].h >= 0.0)) --> "Variable violating min constraint: 0.0 <= zone.airpath[2].h, has value: -1.4" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Airflow/Multizone/MediumColumn.mo:10:3-10:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zone.airpath[1].h >= 0.0)) --> "Variable violating min constraint: 0.0 <= zone.airpath[1].h, has value: -1.4" LOG_ASSERT | debug | Division by zero 0.622 / x in function context LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | Division by zero 0.622 / x in function context LOG_ASSERT | debug | Division by zero 0.622 / x in function context LOG_ASSERT | debug | Division by zero 0.622 / x in function context LOG_ASSERT | debug | Solving non-linear system 291 failed at time=0. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.BuildingSystems_BuildingSystems_Buildings_Zones_Examples_SingleZoneVentilated" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors