(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Bodylight_Bodylight_Hydraulic_Examples_MeursModel2011_HemodynamicsMeurs_flatNorm_fmu --startTime=0 --stopTime=5 --stepSize=0.002 --timeout=50 --tolerance=1e-06 ../Bodylight_Bodylight_Hydraulic_Examples_MeursModel2011_HemodynamicsMeurs_flatNorm.fmu) warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: *** FMU Simulation Info *** - model : Bodylight.Hydraulic.Examples.MeursModel2011.HemodynamicsMeurs_flatNorm (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 5.000000 - tolerance : 1e-06 - stepSize : 0.002 info: maximum step size for 'HemodynamicsMeurs_flatNorm.root': 0.002000 info: Result file: Bodylight_Bodylight_Hydraulic_Examples_MeursModel2011_HemodynamicsMeurs_flatNorm_res.mat (bufferSize=10) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Bodylight 1.1.0/Hydraulic.mo:1580:7-1580:113:writable] | | | | The following assertion has been violated at time 0.626000 | | | | ((LeftVentricle.volume >= -2.220446049250313e-16)) --> "Collapsing of vessels are not supported!" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Bodylight 1.1.0/Hydraulic.mo:1580:7-1580:113:writable] | | | | The following assertion has been violated at time 0.748000 | | | | ((LeftAtrium.volume >= -2.220446049250313e-16)) --> "Collapsing of vessels are not supported!" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Bodylight 1.1.0/Hydraulic.mo:1580:7-1580:113:writable] | | | | The following assertion has been violated at time 1.378000 | | | | ((Epv.volume >= -2.220446049250313e-16)) --> "Collapsing of vessels are not supported!" error: [doStepCVODE] CVode failed with flag = -1 warning: Bad return code at time 2.953817 Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 266, in main handler(args.model, args) File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 140, in _runFMU fmu.simulate() File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 904, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: Final Statistics for 'HemodynamicsMeurs_flatNorm.root': NumSteps = 2098 NumRhsEvals = 12821 NumLinSolvSetups = 3071 NumNonlinSolvIters = 12820 NumNonlinSolvConvFails = 2141 NumErrTestFails = 4 info: 3 warnings info: 1 errors