Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Processes.Tests.CentrifugalPumpCharacteristics.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001313/0.001313, allocations: 99.64 kB / 18.95 MB, free: 2.668 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001749/0.001749, allocations: 213.8 kB / 22.24 MB, free: 5.262 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.408/1.408, allocations: 230.6 MB / 256 MB, free: 7.793 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.7408/0.7408, allocations: 100.9 MB / 413.3 MB, free: 2.871 MB / 318.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Processes.Tests.CentrifugalPumpCharacteristics,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Processes_Tests_CentrifugalPumpCharacteristics",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Processes.Tests.CentrifugalPumpCharacteristics,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Processes_Tests_CentrifugalPumpCharacteristics",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002489/0.002489, allocations: 93.25 kB / 0.5641 GB, free: 35.66 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1111/0.1136, allocations: 74.61 MB / 0.637 GB, free: 6.449 MB / 478.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Processes.Tests.CentrifugalPumpCharacteristics): time 0.05958/0.1732, allocations: 49.39 MB / 0.6852 GB, free: 4.887 MB / 0.5137 GB Notification: Performance of NFInst.instExpressions: time 0.0312/0.2044, allocations: 23.81 MB / 0.7084 GB, free: 13 MB / 0.545 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0009541/0.2054, allocations: 51.56 kB / 0.7085 GB, free: 12.95 MB / 0.545 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Processes/Internal/CentrifugalPump/Measurements/GenericPump.mo:9:41-9:59:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Processes/Internal/CentrifugalPump/Measurements/GenericPump.mo:9:3-10:50:writable] Error: Non-array modification '\"m3/h\"' for array component 'displayUnit', possibly due to missing 'each'. Notification: Performance of FrontEnd: time 0.0009784/0.2064, allocations: 238.5 kB / 0.7087 GB, free: 12.71 MB / 0.545 GB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.4055504058487713] Failed to read output from testmodel.py, exit status != 0: 0.2127866642549634 0.22812564099999996 -1.0 Calling exit ...