python3 -m fmpy simulate --output-file ThermofluidStream_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise4DieselEngine.PolytropicFlow_fmpy_res.csv --start-time 0 --stop-time 1 --timeout 1200 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 0.01 ThermofluidStream_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise4DieselEngine_PolytropicFlow.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Idealized/Processes/Isobaric.mo:22:3-25:146:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_out_fixed >= 273.15 and combustion.T_out_fixed <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out_fixed <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Idealized/Processes/Isobaric.mo:69:3-70:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_out >= 273.15 and combustion.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((compression.outlet.state.T >= 273.15 and compression.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= compression.outlet.state.T <= 373.15, has value: 1050.09" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Idealized/Processes/PolytropicPerfectGas.mo:105:3-106:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((compression.T_out >= 273.15 and compression.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= compression.T_out <= 373.15, has value: 1050.09" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.outlet.state.T >= 273.15 and combustion.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.outlet.state.T <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Idealized/Processes/Isobaric.mo:67:3-68:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_in >= 273.15 and combustion.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_in <= 373.15, has value: 1050.09" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Idealized/Processes/PolytropicPerfectGas.mo:92:3-92:80:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.T_in >= 273.15 and expansion.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.T_in <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Idealized/Processes/PolytropicPerfectGas.mo:105:3-106:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((expansion.T_out >= 273.15 and expansion.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= expansion.T_out <= 373.15, has value: 588.765" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Idealized/Processes/Isochoric.mo:60:3-61:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((gasExchange.T_in >= 273.15 and gasExchange.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= gasExchange.T_in <= 373.15, has value: 588.765" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Utilities/showRealValue.mo:7:3-8:67:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((exhaustTemperature.number >= 273.15 and exhaustTemperature.number <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= exhaustTemperature.number <= 373.15, has value: 588.765"