python3 -m fmpy simulate --output-file AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.StaticValidation_res.csv --start-time 0 --stop-time 29600 --timeout 50 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 1 AixLib_AixLib_Fluid_MassExchangers_MembraneBasedEnthalpyExchangers_Validation_StaticValidation.fmu LOG_STDOUT | info | ... loading "Boundary" from "/tmp/tmp3946stjv/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationEta.txt" LOG_STDOUT | info | ... loading "Boundary" from "/tmp/tmp3946stjv/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationOda.txt" LOG_STDOUT | info | ... loading "Result" from "/tmp/tmp3946stjv/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationResult.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in StaticValidation.fan: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in StaticValidation.fan1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | debug | division by zero at time 0, (a=184) / (b=0), where divisor b expression is: $cse69 Traceback (most recent call last): File "/usr/lib/python3.10/runpy.py", line 196, in _run_module_as_main return _run_code(code, main_globals, None, File "/usr/lib/python3.10/runpy.py", line 86, in _run_code exec(code, run_globals) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/__main__.py", line 4, in main() File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/command_line.py", line 169, in main result = simulate_fmu(args.fmu_filename, File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/simulation.py", line 759, in simulate_fmu result = simulateME(model_description, fmu, start_time, stop_time, solver, step_size, relative_tolerance, start_values, apply_default_start_values, input, output, output_interval, record_events, timeout, step_finished, validate, set_stop_time) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/simulation.py", line 933, in simulateME fmu.exitInitializationMode() File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/fmi2.py", line 280, in exitInitializationMode return self.fmi2ExitInitializationMode(self.component) File "/home/hudson/saved_omc/libraries/.local/lib/python3.10/site-packages/fmpy/fmi2.py", line 215, in w raise FMICallException(function=fname, status=res) fmpy.fmi1.FMICallException: fmi2ExitInitializationMode failed with status 3 (error).