Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.0008604/0.0008604, allocations: 39.66 kB / 22.69 MB, free: 3.141 MB / 13.93 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo): time 0.6617/0.6617, allocations: 128.5 MB / 154.2 MB, free: 13.51 MB / 122.8 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/package.mo): time 0.1373/0.1373, allocations: 22.54 MB / 207.7 MB, free: 4.887 MB / 154.8 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001493/0.001493, allocations: 113.8 kB / 245 MB, free: 1.945 MB / 186.8 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.00257/0.00257, allocations: 222.5 kB / 282.5 MB, free: 12.39 MB / 234.8 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.139/1.139, allocations: 230.6 MB / 0.5375 GB, free: 16.59 MB / 346.8 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2/package.mo): time 2.103/2.103, allocations: 0.4885 GB / 1.114 GB, free: 15.93 MB / 0.7762 GB " [Timeout remaining time 177] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Thermal/package.mo:2:1-91:12:writable] Warning: The package.order file contains a class FluidPortOut_simple, which is expected to be stored in file FluidPortOut_simple.mo, but seems to be named fluidPortOut_simple.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Thermal/package.mo:2:1-91:12:writable] Warning: The package.order file contains a class FluidPortIn_simple, which is expected to be stored in file FluidPortIn_simple.mo, but seems to be named fluidPortIn_simple.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Thermal/fluidPortOut_simple.mo:2:1-49:24:writable] Warning: Expected the package to have name fluidPortOut_simple, but got FluidPortOut_simple. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Thermal/fluidPortIn_simple.mo:2:1-50:23:writable] Warning: Expected the package to have name fluidPortIn_simple, but got FluidPortIn_simple. Proceeding since only the case of the names are different. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/package.mo): time 1.135/1.135, allocations: 312 MB / 1.627 GB, free: 8.457 MB / 1.136 GB " [Timeout remaining time 177] Using package TransiEnt with version 2.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/package.mo) Using package Buildings with version 12.1.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Using package TILMedia with version 1.8.1 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/package.mo) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo) Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo) Running command: setCommandLineOptions("--fmiFlags=s:cvode") Running command: "" <> buildModelFMU(TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating,fileNamePrefix="TransiEnt_TransiEnt_Consumer_Heat_SpaceHeating_Check_TestRoomFloorHeating",fmuType="me_cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating,fileNamePrefix="TransiEnt_TransiEnt_Consumer_Heat_SpaceHeating_Check_TestRoomFloorHeating",fmuType="me_cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ClaRa requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: TILMedia requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: TransiEnt requested package Buildings of version 12.0.0. Buildings 12.1.2 is used instead which states that it is fully compatible without conversion script needed. Notification: TransiEnt requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.006289/0.006289, allocations: 243.6 kB / 2.198 GB, free: 13.12 MB / 1.433 GB Notification: Performance of FrontEnd - Absyn->SCode: time 2.322/2.328, allocations: 280.5 MB / 2.472 GB, free: 15.81 MB / 1.636 GB Notification: Performance of NFInst.instantiate(TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating): time 0.01448/2.343, allocations: 14.58 MB / 2.486 GB, free: 4.805 MB / 1.636 GB Notification: Performance of NFInst.instExpressions: time 0.01821/2.361, allocations: 12.65 MB / 2.498 GB, free: 10.82 MB / 1.652 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.003298/2.364, allocations: 86.62 kB / 2.498 GB, free: 10.77 MB / 1.652 GB Notification: Performance of NFTyping.typeComponents: time 0.004937/2.369, allocations: 1.808 MB / 2.5 GB, free: 9.605 MB / 1.652 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Functions/fullPathName.mo:2:1-76:17:writable] Warning: Pure function 'TransiEnt.Basics.Functions.fullPathName' contains a call to impure function 'Modelica.Utilities.Streams.print'. Notification: Performance of NFTyping.typeBindings: time 0.00537/2.375, allocations: 1.865 MB / 2.502 GB, free: 8.152 MB / 1.652 GB Notification: Performance of NFTyping.typeClassSections: time 0.004178/2.379, allocations: 1.776 MB / 2.504 GB, free: 6.715 MB / 1.652 GB Notification: Performance of NFFlatten.flatten: time 0.00762/2.386, allocations: 4.834 MB / 2.508 GB, free: 3.797 MB / 1.652 GB Notification: Performance of NFFlatten.resolveConnections: time 0.003012/2.389, allocations: 1.655 MB / 2.51 GB, free: 2.594 MB / 1.652 GB Notification: Performance of NFEvalConstants.evaluate: time 0.004305/2.394, allocations: 2.277 MB / 2.512 GB, free: 1.363 MB / 1.652 GB Notification: Performance of NFSimplifyModel.simplify: time 0.003581/2.397, allocations: 1.99 MB / 2.514 GB, free: 80 kB / 1.652 GB Notification: Performance of NFPackage.collectConstants: time 0.001446/2.399, allocations: 367.5 kB / 2.515 GB, free: 80 kB / 1.652 GB Notification: Performance of NFFlatten.collectFunctions: time 0.00288/2.402, allocations: 0.8911 MB / 2.515 GB, free: 15.79 MB / 1.667 GB Notification: Performance of NFScalarize.scalarize: time 0.001412/2.403, allocations: 1.346 MB / 2.517 GB, free: 14.82 MB / 1.667 GB Notification: Performance of NFVerifyModel.verify: time 0.003351/2.406, allocations: 1.672 MB / 2.518 GB, free: 13.34 MB / 1.667 GB Notification: Performance of NFConvertDAE.convert: time 0.007582/2.414, allocations: 6.252 MB / 2.525 GB, free: 7.062 MB / 1.667 GB Notification: Performance of FrontEnd - DAE generated: time 6.832e-06/2.414, allocations: 4 kB / 2.525 GB, free: 7.059 MB / 1.667 GB Notification: Performance of FrontEnd: time 2.154e-06/2.414, allocations: 0 / 2.525 GB, free: 7.059 MB / 1.667 GB Notification: Performance of Transformations before backend: time 0.0001983/2.414, allocations: 0 / 2.525 GB, free: 7.059 MB / 1.667 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 543 * Number of variables: 543 Notification: Performance of Generate backend data structure: time 0.008806/2.423, allocations: 5.685 MB / 2.53 GB, free: 1.285 MB / 1.667 GB Notification: Performance of prepare preOptimizeDAE: time 5.71e-05/2.423, allocations: 8.031 kB / 2.53 GB, free: 1.277 MB / 1.667 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.0003553/2.423, allocations: 284 kB / 2.53 GB, free: 0.9883 MB / 1.667 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.001355/2.425, allocations: 0.6455 MB / 2.531 GB, free: 348 kB / 1.667 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.007035/2.432, allocations: 4.428 MB / 2.535 GB, free: 11.82 MB / 1.683 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0001868/2.432, allocations: 203.2 kB / 2.535 GB, free: 11.61 MB / 1.683 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0002527/2.432, allocations: 180 kB / 2.536 GB, free: 11.44 MB / 1.683 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.003201/2.435, allocations: 2.914 MB / 2.539 GB, free: 8.008 MB / 1.683 GB Notification: Performance of preOpt findStateOrder (simulation): time 4.303e-05/2.435, allocations: 23.75 kB / 2.539 GB, free: 7.984 MB / 1.683 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0001232/2.436, allocations: 91.98 kB / 2.539 GB, free: 7.895 MB / 1.683 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 3.099e-05/2.436, allocations: 52 kB / 2.539 GB, free: 7.844 MB / 1.683 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.002211/2.438, allocations: 1.605 MB / 2.54 GB, free: 6.23 MB / 1.683 GB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.01233/2.45, allocations: 14.77 MB / 2.555 GB, free: 6.949 MB / 1.698 GB Notification: Performance of preOpt comSubExp (simulation): time 0.002031/2.452, allocations: 1.403 MB / 2.556 GB, free: 5.434 MB / 1.698 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.0008303/2.453, allocations: 0.657 MB / 2.557 GB, free: 4.742 MB / 1.698 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0001247/2.453, allocations: 52.91 kB / 2.557 GB, free: 4.691 MB / 1.698 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.001098/2.454, allocations: 1.081 MB / 2.558 GB, free: 3.5 MB / 1.698 GB Notification: Performance of preOpt simplifyInStream (simulation): time 0.0009399/2.455, allocations: 210.3 kB / 2.558 GB, free: 3.293 MB / 1.698 GB Notification: Performance of pre-optimization done (n=262): time 6.803e-06/2.455, allocations: 0 / 2.558 GB, free: 3.293 MB / 1.698 GB Notification: Performance of matching and sorting (n=272): time 0.01784/2.473, allocations: 21.47 MB / 2.579 GB, free: 13.64 MB / 1.73 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0002349/2.473, allocations: 0.7219 MB / 2.58 GB, free: 12.75 MB / 1.73 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.004957/2.478, allocations: 4.607 MB / 2.584 GB, free: 8.176 MB / 1.73 GB Notification: Performance of collectPreVariables (initialization): time 0.0003233/2.479, allocations: 89.62 kB / 2.584 GB, free: 8.082 MB / 1.73 GB Notification: Performance of collectInitialEqns (initialization): time 0.001194/2.48, allocations: 1.897 MB / 2.586 GB, free: 6.172 MB / 1.73 GB Notification: Performance of collectInitialBindings (initialization): time 0.0006789/2.48, allocations: 0.8715 MB / 2.587 GB, free: 5.293 MB / 1.73 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.0007403/2.481, allocations: 0.6471 MB / 2.588 GB, free: 4.637 MB / 1.73 GB Notification: Performance of setup shared object (initialization): time 6.632e-05/2.481, allocations: 301.1 kB / 2.588 GB, free: 4.34 MB / 1.73 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.001038/2.482, allocations: 0.7417 MB / 2.589 GB, free: 3.59 MB / 1.73 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.001369/2.484, allocations: 1.715 MB / 2.59 GB, free: 1.434 MB / 1.73 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.002331/2.486, allocations: 2.539 MB / 2.593 GB, free: 14.46 MB / 1.745 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 1.477e-05/2.486, allocations: 8 kB / 2.593 GB, free: 14.46 MB / 1.745 GB Notification: Performance of matching and sorting (n=435) (initialization): time 0.003935/2.49, allocations: 2.941 MB / 2.596 GB, free: 11.51 MB / 1.745 GB Notification: Performance of prepare postOptimizeDAE: time 3.277e-05/2.49, allocations: 16 kB / 2.596 GB, free: 11.49 MB / 1.745 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 7.558e-05/2.49, allocations: 75.94 kB / 2.596 GB, free: 11.42 MB / 1.745 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.0002585/2.49, allocations: 100.8 kB / 2.596 GB, free: 11.32 MB / 1.745 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.0008036/2.491, allocations: 467.4 kB / 2.596 GB, free: 10.86 MB / 1.745 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.0003633/2.491, allocations: 0.6302 MB / 2.597 GB, free: 10.2 MB / 1.745 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.001428/2.493, allocations: 115.9 kB / 2.597 GB, free: 10.09 MB / 1.745 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0001412/2.493, allocations: 128 kB / 2.597 GB, free: 9.965 MB / 1.745 GB Notification: Performance of preBalanceInitialSystem (initialization_lambda0): time 0.002301/2.495, allocations: 1.619 MB / 2.599 GB, free: 8.34 MB / 1.745 GB Notification: Performance of partitionIndependentBlocks (initialization_lambda0): time 0.001406/2.497, allocations: 1.711 MB / 2.6 GB, free: 6.191 MB / 1.745 GB Notification: Performance of analyzeInitialSystem (initialization_lambda0): time 0.002227/2.499, allocations: 2.523 MB / 2.603 GB, free: 3.238 MB / 1.745 GB Notification: Performance of solveInitialSystemEqSystem (initialization_lambda0): time 1.338e-05/2.499, allocations: 8 kB / 2.603 GB, free: 3.23 MB / 1.745 GB Notification: Performance of matching and sorting (n=435) (initialization_lambda0): time 0.003677/2.503, allocations: 2.913 MB / 2.606 GB, free: 304 kB / 1.745 GB Notification: Performance of prepare postOptimizeDAE: time 2.43e-05/2.503, allocations: 20 kB / 2.606 GB, free: 284 kB / 1.745 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 6.367e-05/2.503, allocations: 72.83 kB / 2.606 GB, free: 212 kB / 1.745 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.0001838/2.503, allocations: 104.8 kB / 2.606 GB, free: 104 kB / 1.745 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.0007792/2.504, allocations: 459.2 kB / 2.606 GB, free: 15.65 MB / 1.761 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.0003853/2.504, allocations: 0.6344 MB / 2.607 GB, free: 14.99 MB / 1.761 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.001462/2.506, allocations: 103.9 kB / 2.607 GB, free: 14.89 MB / 1.761 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0001286/2.506, allocations: 132 kB / 2.607 GB, free: 14.76 MB / 1.761 GB Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 140 * Number of states: 0 () * Number of discrete variables: 109 ($PRE.onOffRelais.t_min_off_passed.enableFire,$PRE.onOffRelais.switch_to_on.enableFire,$PRE.onOffRelais.t_min_on_passed.enableFire,$PRE.onOffRelais.switch_to_off.enableFire,$PRE.onOffRelais.initOffReady.enableFire,$PRE.onOffRelais.initOnReady.enableFire,$PRE.onOffRelais.initOffBlocked.enableFire,$PRE.onOffRelais.initOnBlocked.enableFire,$PRE.simCenter.ambientConditions.temperature.MSL_combiTimeTable.nextTimeEvent,$whenCondition7,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$whenCondition2,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$whenCondition1,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,onOffRelais.switch_to_on.t_start,$PRE.onOffRelais.switch_to_on.t_start,onOffRelais.switch_to_off.t_start,$PRE.onOffRelais.switch_to_off.t_start,onOffRelais.initOffReady.t_start,$PRE.onOffRelais.initOffReady.t_start,onOffRelais.initOnReady.t_start,$PRE.onOffRelais.initOnReady.t_start,onOffRelais.t_min_on_passed.condition,onOffRelais.t_min_off_passed.condition,onOffRelais.stateGraphRoot.resume,onOffRelais.stateGraphRoot.suspend,onOffRelais.initOnBlocked.condition,onOffRelais.initOffBlocked.condition,onOffRelais.initOnReady.condition,onOffRelais.initOffReady.condition,onOffRelais.initOnBlocked.t_start,$PRE.onOffRelais.initOnBlocked.t_start,onOffRelais.initOnBlocked.fire,onOffRelais.initOnBlocked.enableFire,onOffRelais.initOffBlocked.t_start,$PRE.onOffRelais.initOffBlocked.t_start,onOffRelais.initOffBlocked.fire,onOffRelais.initOffBlocked.enableFire,onOffRelais.initOnReady.enableFire,onOffRelais.initOffReady.enableFire,onOffRelais.init.oldActive,$PRE.onOffRelais.init.oldActive,onOffRelais.init.newActive,$PRE.onOffRelais.init.newActive,onOffRelais.init.outPort[4].available,onOffRelais.init.outPort[3].available,onOffRelais.init.outPort[2].available,onOffRelais.init.localActive,$PRE.onOffRelais.init.localActive,onOffRelais.init.active,onOffRelais.switch_to_off.enableFire,onOffRelais.on_ready.active,onOffRelais.on_ready.oldActive,$PRE.onOffRelais.on_ready.oldActive,onOffRelais.on_ready.newActive,$PRE.onOffRelais.on_ready.newActive,onOffRelais.on_ready.inPort[2].occupied,onOffRelais.on_ready.localActive,$PRE.onOffRelais.on_ready.localActive,onOffRelais.t_min_on_passed.t_start,$PRE.onOffRelais.t_min_on_passed.t_start,onOffRelais.t_min_on_passed.fire,onOffRelais.t_min_on_passed.enableFire,onOffRelais.switch_to_on.enableFire,onOffRelais.off_blocked.oldActive,$PRE.onOffRelais.off_blocked.oldActive,onOffRelais.off_blocked.newActive,$PRE.onOffRelais.off_blocked.newActive,onOffRelais.off_blocked.inPort[2].occupied,onOffRelais.off_blocked.localActive,$PRE.onOffRelais.off_blocked.localActive,onOffRelais.off_blocked.active,onOffRelais.on_blocked.active,onOffRelais.on_blocked.oldActive,$PRE.onOffRelais.on_blocked.oldActive,onOffRelais.on_blocked.newActive,$PRE.onOffRelais.on_blocked.newActive,onOffRelais.on_blocked.inPort[2].occupied,onOffRelais.on_blocked.localActive,$PRE.onOffRelais.on_blocked.localActive,onOffRelais.off_ready.oldActive,$PRE.onOffRelais.off_ready.oldActive,onOffRelais.off_ready.newActive,$PRE.onOffRelais.off_ready.newActive,onOffRelais.off_ready.inPort[2].occupied,onOffRelais.off_ready.localActive,$PRE.onOffRelais.off_ready.localActive,onOffRelais.off_ready.active,onOffRelais.t_min_off_passed.t_start,$PRE.onOffRelais.t_min_off_passed.t_start,onOffRelais.t_min_off_passed.fire,onOffRelais.t_min_off_passed.enableFire,onOffRelais.stateGraphRoot.activeSteps,onOffRelais.y,simCenter.ambientConditions.temperature.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.ambientConditions.temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.ambientConditions.temperature.MSL_combiTimeTable.nextTimeEvent,ctrl.y,$PRE.ctrl.y,$whenCondition3,$whenCondition4,$whenCondition5,$whenCondition6) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (326): * Single equations (assignments): 310 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 15 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(1,4)} Notification: Performance of prepare postOptimizeDAE: time 0.0004815/2.506, allocations: 440.5 kB / 2.608 GB, free: 14.31 MB / 1.761 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.0004787/2.507, allocations: 0.516 MB / 2.608 GB, free: 13.79 MB / 1.761 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.00247/2.509, allocations: 1.839 MB / 2.61 GB, free: 11.94 MB / 1.761 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 1.936e-05/2.509, allocations: 27.98 kB / 2.61 GB, free: 11.91 MB / 1.761 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.192e-05/2.509, allocations: 8 kB / 2.61 GB, free: 11.9 MB / 1.761 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 1.551e-05/2.509, allocations: 15.97 kB / 2.61 GB, free: 11.89 MB / 1.761 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.00547/2.515, allocations: 4.11 MB / 2.614 GB, free: 7.727 MB / 1.761 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 5.784e-05/2.515, allocations: 47.95 kB / 2.614 GB, free: 7.68 MB / 1.761 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.0005046/2.515, allocations: 215.6 kB / 2.614 GB, free: 7.469 MB / 1.761 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.0001919/2.515, allocations: 68.8 kB / 2.614 GB, free: 7.398 MB / 1.761 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0001055/2.515, allocations: 51.97 kB / 2.614 GB, free: 7.348 MB / 1.761 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.0003209/2.516, allocations: 0.5836 MB / 2.615 GB, free: 6.738 MB / 1.761 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 5.25e-06/2.516, allocations: 11.94 kB / 2.615 GB, free: 6.727 MB / 1.761 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.00391/2.52, allocations: 3.26 MB / 2.618 GB, free: 3.328 MB / 1.761 GB Notification: Performance of postOpt removeConstants (simulation): time 0.001514/2.521, allocations: 0.8618 MB / 2.619 GB, free: 2.457 MB / 1.761 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.0003274/2.522, allocations: 47.98 kB / 2.619 GB, free: 2.41 MB / 1.761 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.0006593/2.522, allocations: 67.89 kB / 2.619 GB, free: 2.344 MB / 1.761 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0002778/2.522, allocations: 196.9 kB / 2.619 GB, free: 2.152 MB / 1.761 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 8.807e-05/2.523, allocations: 67.97 kB / 2.619 GB, free: 2.086 MB / 1.761 GB Notification: Performance of sorting global known variables: time 0.003663/2.526, allocations: 3.008 MB / 2.622 GB, free: 15.1 MB / 1.777 GB Notification: Performance of sort global known variables: time 1.8e-07/2.526, allocations: 0 / 2.622 GB, free: 15.1 MB / 1.777 GB Notification: Performance of remove unused functions: time 0.003067/2.529, allocations: 1.171 MB / 2.623 GB, free: 13.93 MB / 1.777 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 26 * Number of states: 5 (roomFloorHeating.Q_needed,roomFloorHeating.T_room,roomFloorHeating.T_floor,roomFloorHeating.T_wallInside,roomFloorHeating.T_wallInternal) * Number of discrete variables: 63 (onOffRelais.initOnReady.t_start,onOffRelais.initOffReady.t_start,onOffRelais.switch_to_off.t_start,onOffRelais.switch_to_on.t_start,$whenCondition1,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition2,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,onOffRelais.initOnBlocked.enableFire,onOffRelais.initOffBlocked.enableFire,onOffRelais.t_min_off_passed.enableFire,onOffRelais.off_ready.localActive,onOffRelais.on_blocked.active,onOffRelais.t_min_on_passed.enableFire,onOffRelais.off_blocked.localActive,onOffRelais.on_ready.active,onOffRelais.init.localActive,$whenCondition7,$whenCondition6,$whenCondition5,$whenCondition4,$whenCondition3,ctrl.y,simCenter.ambientConditions.temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.ambientConditions.temperature.MSL_combiTimeTable.nextTimeEventScaled,onOffRelais.y,onOffRelais.stateGraphRoot.activeSteps,onOffRelais.t_min_off_passed.fire,onOffRelais.t_min_off_passed.t_start,onOffRelais.off_ready.active,onOffRelais.off_ready.inPort[2].occupied,onOffRelais.off_ready.newActive,onOffRelais.off_ready.oldActive,onOffRelais.on_blocked.localActive,onOffRelais.on_blocked.inPort[2].occupied,onOffRelais.on_blocked.newActive,onOffRelais.on_blocked.oldActive,onOffRelais.off_blocked.active,onOffRelais.off_blocked.inPort[2].occupied,onOffRelais.off_blocked.newActive,onOffRelais.off_blocked.oldActive,onOffRelais.switch_to_on.enableFire,onOffRelais.t_min_on_passed.fire,onOffRelais.t_min_on_passed.t_start,onOffRelais.on_ready.localActive,onOffRelais.on_ready.inPort[2].occupied,onOffRelais.on_ready.newActive,onOffRelais.on_ready.oldActive,onOffRelais.switch_to_off.enableFire,onOffRelais.init.active,onOffRelais.init.outPort[2].available,onOffRelais.init.outPort[3].available,onOffRelais.init.outPort[4].available,onOffRelais.init.newActive,onOffRelais.init.oldActive,onOffRelais.initOffReady.enableFire,onOffRelais.initOnReady.enableFire,onOffRelais.initOffBlocked.fire,onOffRelais.initOffBlocked.t_start,onOffRelais.initOnBlocked.fire,onOffRelais.initOnBlocked.t_start) * Number of discrete states: 16 (simCenter.ambientConditions.temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.ambientConditions.temperature.MSL_combiTimeTable.nextTimeEventScaled,onOffRelais.init.newActive,onOffRelais.on_ready.newActive,onOffRelais.off_blocked.newActive,onOffRelais.on_blocked.newActive,onOffRelais.off_ready.newActive,ctrl.y,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,onOffRelais.switch_to_on.t_start,onOffRelais.switch_to_off.t_start,onOffRelais.initOffReady.t_start,onOffRelais.initOnReady.t_start) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (168): * Single equations (assignments): 133 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 15 * When equations: 19 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(1,4)} [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-ClaRa/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Resources/Library/libTILMedia181ClaRa.so Notification: Performance of Backend phase and start with SimCode phase: time 0.006917/2.536, allocations: 5.191 MB / 2.628 GB, free: 9.094 MB / 1.777 GB Notification: Performance of simCode: created initialization part: time 0.004927/2.541, allocations: 3.953 MB / 2.632 GB, free: 4.965 MB / 1.777 GB Notification: Performance of simCode: created event and clocks part: time 9.918e-06/2.541, allocations: 0 / 2.632 GB, free: 4.965 MB / 1.777 GB Notification: Performance of simCode: created simulation system equations: time 0.001442/2.543, allocations: 1.299 MB / 2.634 GB, free: 3.578 MB / 1.777 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.002453/2.545, allocations: 0.7079 MB / 2.634 GB, free: 2.891 MB / 1.777 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.03904/2.584, allocations: 29.45 MB / 2.663 GB, free: 3.969 MB / 1.808 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.001637/2.586, allocations: 1.949 MB / 2.665 GB, free: 1.98 MB / 1.808 GB Notification: Performance of simCode: alias equations: time 0.001871/2.588, allocations: 0.7651 MB / 2.666 GB, free: 1.227 MB / 1.808 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.001546/2.589, allocations: 1.71 MB / 2.667 GB, free: 15.51 MB / 1.823 GB Notification: Performance of SimCode: time 1.362e-06/2.589, allocations: 0 / 2.667 GB, free: 15.51 MB / 1.823 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.1668/2.756, allocations: 80.1 MB / 2.746 GB, free: 204 kB / 1.886 GB Notification: Performance of buildModelFMU: Generate platform static: time 11.59/14.35, allocations: 6.406 kB / 2.746 GB, free: 200 kB / 1.886 GB " [Timeout remaining time 645] (rm -f TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating.pipe ; mkfifo TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating.pipe ; head -c 1048576 < TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating.pipe >> ../files/TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating.sim & (cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_TransiEnt_TransiEnt_Consumer_Heat_SpaceHeating_Check_TestRoomFloorHeating_fmu --startTime=0 --stopTime=604800 --stepSize=900 --mode=me --timeout=240 --tolerance=1e-06 ../TransiEnt_TransiEnt_Consumer_Heat_SpaceHeating_Check_TestRoomFloorHeating.fmu) > TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating.pipe 2>&1) [Timeout 252.0] (rm -f TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_OMSimulator-cs-cvode.pipe ; mkfifo TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_OMSimulator-cs-cvode.pipe ; head -c 1048576 < TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_OMSimulator-cs-cvode.pipe >> /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_OMSimulator-cs-cvode.sim & (cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_TransiEnt_TransiEnt_Consumer_Heat_SpaceHeating_Check_TestRoomFloorHeating_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=604800 --stepSize=900 --mode=cs --timeout=240 --tolerance=1e-06 ../TransiEnt_TransiEnt_Consumer_Heat_SpaceHeating_Check_TestRoomFloorHeating_OMSimulator-cs-cvode.fmu) > TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_OMSimulator-cs-cvode.pipe 2>&1) [Timeout 252.0] (rm -f TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_OMSimulator-cs-euler.pipe ; mkfifo TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_OMSimulator-cs-euler.pipe ; head -c 1048576 < TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_OMSimulator-cs-euler.pipe >> /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_OMSimulator-cs-euler.sim & (cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_TransiEnt_TransiEnt_Consumer_Heat_SpaceHeating_Check_TestRoomFloorHeating_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=604800 --stepSize=900 --mode=cs --timeout=240 --tolerance=1e-06 ../TransiEnt_TransiEnt_Consumer_Heat_SpaceHeating_Check_TestRoomFloorHeating_OMSimulator-cs-euler.fmu) > TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_OMSimulator-cs-euler.pipe 2>&1) [Timeout 252.0] OMSimulator-cs-euler timed out simulating the FMU (rm -f TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_fmpy.pipe ; mkfifo TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_fmpy.pipe ; head -c 1048576 < TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_fmpy.pipe >> /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/files/TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_fmpy.sim & (cd run_fmpy && python3 -m fmpy simulate --output-file ../TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_fmpy_res.csv --start-time 0 --stop-time 604800 --timeout 240 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 900 ../TransiEnt_TransiEnt_Consumer_Heat_SpaceHeating_Check_TestRoomFloorHeating.fmu) > TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.TestRoomFloorHeating_fmpy.pipe 2>&1) [Timeout 252.0] [Calling sys.exit(0), Time elapsed: 32.050651675090194]