(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Pump_dp_tau_centrifugal_Characteristics_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Pump_dp_tau_centrifugal_Characteristics_OMSimulator-cs-euler_fmu --startTime=-1 --stopTime=1.55 --stepSize=0.0100394 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Processes_Tests_Pump_dp_tau_centrifugal_Characteristics_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Processes.Tests.Pump_dp_tau_centrifugal_Characteristics (co-simulation) - fmiVersion: 2.0 - startTime : -1.000000 - stopTime : 1.550000 - tolerance : 1e-06 - stepSize : 0.0100394 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time -1.000000 | | | | ((legacyPump.p_min >= 611.657 and legacyPump.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= legacyPump.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time -1.000000 | | | | ((correctedPump.p_min >= 611.657 and correctedPump.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= correctedPump.p_min <= 1e8, has value: 100" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Processes.Tests.Pump_dp_tau_centrifugal_Characteristics_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable Pump_dp_tau_centrifugal_Characteristics.correctedPump.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.flowSensor.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.flowSensor.quantityString will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.flowSensor1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.flowSensor1.quantityString will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.legacyPump.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.sink.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.sink.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.sink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.sink1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.sink1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.sink1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source1.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Pump_dp_tau_centrifugal_Characteristics.source1.instanceName will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] Pump_dp_tau_centrifugal_Characteristics/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Water/IF97_Utilities.mo:3022: IF97 medium function tsat called with too low pressure p = 100 Pa <= 611.657 Pa (triple point pressure) Segmentation fault (core dumped)