(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise5TurboChargedDieselEngine.Flow_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise5TurboChargedDieselEngine_Flow_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_TUMExercisesThermodynamicCycles_Exercise5TurboChargedDieselEngine_Flow_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise5TurboChargedDieselEngine.Flow (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.01 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Examples/TUMExercisesThermodynamicCycles/Exercise5TurboChargedDieselEngine/BaseModel.mo:16:3-16:87:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((T5 >= 273.15 and T5 <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= T5 <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/Isobaric.mo:22:3-25:146:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_out_fixed >= 273.15 and combustion.T_out_fixed <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out_fixed <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/Isobaric.mo:69:3-70:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_out >= 273.15 and combustion.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((engineCompression.outlet.state.T >= 273.15 and engineCompression.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= engineCompression.outlet.state.T <= 373.15, has value: 997.23" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/PolytropicPerfectGas.mo:105:3-106:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((engineCompression.T_out >= 273.15 and engineCompression.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= engineCompression.T_out <= 373.15, has value: 997.23" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.outlet.state.T >= 273.15 and combustion.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.outlet.state.T <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/Isobaric.mo:67:3-68:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_in >= 273.15 and combustion.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_in <= 373.15, has value: 997.23" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((engineExpansion.outlet.state.T >= 273.15 and engineExpansion.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= engineExpansion.outlet.state.T <= 373.15, has value: 632.903" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/PolytropicPerfectGas.mo:92:3-92:80:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((engineExpansion.T_in >= 273.15 and engineExpansion.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= engineExpansion.T_in <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/PolytropicPerfectGas.mo:105:3-106:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((engineExpansion.T_out >= 273.15 and engineExpansion.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= engineExpansion.T_out <= 373.15, has value: 632.903" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.outlet.state.T >= 273.15 and turbine.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= turbine.outlet.state.T <= 373.15, has value: 616.874" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.adiabaticModel.state_in.T >= 273.15 and turbine.adiabaticModel.state_in.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.state_in.T <= 373.15, has value: 632.903" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:25:3-26:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.adiabaticModel.T_in >= 273.15 and turbine.adiabaticModel.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.T_in <= 373.15, has value: 632.903" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:27:3-27:62:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.adiabaticModel.T_out_is >= 273.15 and turbine.adiabaticModel.T_out_is <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.T_out_is <= 373.15, has value: 616.874" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.adiabaticModel.state_out.T >= 273.15 and turbine.adiabaticModel.state_out.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.state_out.T <= 373.15, has value: 616.874" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/AdiabaticThermodynamicModels/PerfectGas.mo:20:3-20:48:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.adiabaticModel.T_out >= 273.15 and turbine.adiabaticModel.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.T_out <= 373.15, has value: 616.874" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise5TurboChargedDieselEngine.Flow_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable Flow.combustion.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Flow.compressor.adiabaticModel.name will not be stored in the result file, because the signal type is not supported info: Variable Flow.compressor.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Flow.cooler.instanceName will not be stored in the result file, because the signal type is not supported info: Parameter Flow.efficiency.description will not be stored in the result file, because the signal type is not supported info: Variable Flow.engineCompression.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Flow.engineExpansion.instanceName will not be stored in the result file, because the signal type is not supported info: Parameter Flow.massFlowRate1.description will not be stored in the result file, because the signal type is not supported info: Parameter Flow.power.description will not be stored in the result file, because the signal type is not supported info: Variable Flow.sink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Flow.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Flow.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Flow.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Flow.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Flow.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Flow.turbine.adiabaticModel.name will not be stored in the result file, because the signal type is not supported info: Variable Flow.turbine.instanceName will not be stored in the result file, because the signal type is not supported info: Parameter Flow.turbineWork.description will not be stored in the result file, because the signal type is not supported info: Variable Flow.valve.instanceName will not be stored in the result file, because the signal type is not supported