Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.5548/0.5548, allocations: 145.3 MB / 164.1 MB, free: 11.42 MB / 138.7 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: setCommandLineOptions("--fmiFlags=s:cvode") Running command: "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestDynamicWaterHeating_Islanding",fmuType="me_cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding,fileNamePrefix="ThermoSysPro_ThermoSysPro_Examples_SimpleExamples_TestDynamicWaterHeating_Islanding",fmuType="me_cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.0005036/0.0005036, allocations: 19.97 kB / 242.5 MB, free: 9.301 MB / 202.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1635/0.164, allocations: 33.56 MB / 276.1 MB, free: 9.398 MB / 218.7 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding): time 1.269/1.433, allocations: 326.7 MB / 0.5886 GB, free: 7.984 MB / 458.7 MB Notification: Performance of NFInst.instExpressions: time 0.4801/1.913, allocations: 169.8 MB / 0.7545 GB, free: 2.113 MB / 0.6042 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.00252/1.916, allocations: 43.56 kB / 0.7546 GB, free: 2.113 MB / 0.6042 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SourceP.mo:19:3-20:78:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SinkP.mo:19:3-20:80:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:24:3-25:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:26:3-27:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/TwoPhaseCavity.mo:122:3-123:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/TwoPhaseCavity.mo:124:3-125:82:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/TwoPhaseCavity.mo:132:3-133:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:58:3-59:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:60:3-61:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:36:3-37:78:writable] Warning: Connector C1vap is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:38:3-39:80:writable] Warning: Connector C2ex is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:40:3-41:81:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:42:3-43:79:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:46:3-47:79:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:58:3-59:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:60:3-61:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:58:3-59:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:60:3-61:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:20:3-21:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:22:3-23:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:24:3-25:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:26:3-27:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:20:3-21:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:24:3-25:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:26:3-27:78:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:20:3-21:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:22:3-23:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:24:3-25:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:26:3-27:78:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/Sink.mo:10:3-11:80:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SourceP.mo:19:3-20:78:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/RefQ.mo:7:3-8:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/RefQ.mo:9:3-10:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/IdealCheckValve.mo:12:3-13:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/IdealCheckValve.mo:14:3-15:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:15:3-16:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:17:3-18:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:29:3-30:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:31:3-32:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.001915/1.918, allocations: 0.9134 MB / 0.7554 GB, free: 2.109 MB / 0.6042 GB Notification: Performance of NFTyping.typeBindings: time 0.00379/1.922, allocations: 2.062 MB / 0.7575 GB, free: 2.109 MB / 0.6042 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:470:9-470:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:525:9-525:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:708:9-708:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.0341/1.956, allocations: 13.58 MB / 0.7707 GB, free: 1.805 MB / 0.6042 GB Notification: Performance of NFFlatten.flatten: time 0.01926/1.975, allocations: 26.21 MB / 0.7963 GB, free: 1.727 MB / 0.6042 GB Notification: Performance of NFFlatten.resolveConnections: time 0.01312/1.988, allocations: 7.23 MB / 0.8034 GB, free: 17.39 MB / 0.6198 GB Notification: Performance of NFEvalConstants.evaluate: time 0.01651/2.005, allocations: 8.353 MB / 0.8115 GB, free: 14.32 MB / 0.6198 GB Notification: Performance of NFSimplifyModel.simplify: time 0.01576/2.02, allocations: 8.283 MB / 0.8196 GB, free: 9.645 MB / 0.6198 GB Notification: Performance of NFPackage.collectConstants: time 0.006641/2.027, allocations: 1.797 MB / 0.8214 GB, free: 9.645 MB / 0.6198 GB Notification: Performance of NFFlatten.collectFunctions: time 0.04894/2.076, allocations: 21.5 MB / 0.8424 GB, free: 11.62 MB / 0.6355 GB Notification: Performance of NFScalarize.scalarize: time 0.01137/2.087, allocations: 5.899 MB / 0.8481 GB, free: 5.848 MB / 0.6355 GB Notification: Performance of NFVerifyModel.verify: time 0.02301/2.11, allocations: 7.147 MB / 0.8551 GB, free: 14.8 MB / 0.6511 GB Notification: Performance of NFConvertDAE.convert: time 0.05242/2.163, allocations: 32.49 MB / 0.8868 GB, free: 15.76 MB / 0.6823 GB Notification: Performance of FrontEnd - DAE generated: time 9.649e-06/2.163, allocations: 0 / 0.8868 GB, free: 15.76 MB / 0.6823 GB Notification: Performance of FrontEnd: time 2.885e-06/2.163, allocations: 0.9062 kB / 0.8868 GB, free: 15.76 MB / 0.6823 GB Notification: Performance of Transformations before backend: time 0.0009018/2.164, allocations: 0 / 0.8868 GB, free: 15.76 MB / 0.6823 GB Error: Too few equations, under-determined system. The model has 3749 equation(s) and 3751 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/InstrumentationAndControl/Connectors.mo:36:5-36:22:writable] Warning: Variable regulation_Niveau.MesureDebitVapeur.signal does not have any remaining equation to be solved in. The original equations were: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/InstrumentationAndControl/Connectors.mo:36:5-36:22:writable] Warning: Variable regulation_Niveau.MesureDebitEau.signal does not have any remaining equation to be solved in. The original equations were: " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 3.6180159766227007]