(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ModelicaTest_trunk_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes13_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ModelicaTest_trunk_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes13_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=5 --stepSize=0.0009994 --mode=cs --timeout=240 --tolerance=1e-06 ../ModelicaTest_trunk_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes13_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes13 (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 5.000000 - tolerance : 1e-06 - stepSize : 0.0009994 error: [fmi2logger] [fmi2Error] SeriesPipes13/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Media/Water/IF97_Utilities.mo:6695: Error in region computation of IF97 steam tables(p = 502139, h = 1.58927e+07) error: [fmi2logger] [fmi2Error] SeriesPipes13/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_exitInitializationMode failed for FMU "SeriesPipes13.root.SeriesPipes13" free(): invalid pointer Aborted (core dumped)