(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.MultipleBuildings.TwoIdenticalOneZoneBuildings_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_MultipleBuildings_TwoIdenticalOneZoneBuildings_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=172800 --stepSize=69.12 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_MultipleBuildings_TwoIdenticalOneZoneBuildings_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.MultipleBuildings.TwoIdenticalOneZoneBuildings (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 172800.000000 - tolerance : 1e-06 - stepSize : 69.12 EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.14 11:12 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bui[2].duc.m_flow >= 0.0 and bui[2].duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui[2].duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bui[1].duc.m_flow >= 0.0 and bui[1].duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui[1].duc.m_flow <= 1e5, has value: -6.59347e-15" info: Result file: ../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.MultipleBuildings.TwoIdenticalOneZoneBuildings_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter TwoIdenticalOneZoneBuildings.bui[1].zon.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalOneZoneBuildings.bui[2].zon.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalOneZoneBuildings.bui[1].zon.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter TwoIdenticalOneZoneBuildings.bui[2].zon.zoneName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 276.480000 | | | | ((noEvent(bui[1].zon.vol.medium.T >= 200.0))) --> "In TwoIdenticalOneZoneBuildings.bui[1].zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." error: [fmi2logger] [fmi2Error] TwoIdenticalOneZoneBuildings/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 345.600000 | | | | ((noEvent(bui[2].zon.vol.medium.T >= 200.0))) --> "In TwoIdenticalOneZoneBuildings.bui[2].zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." error: [fmi2logger] [fmi2Error] TwoIdenticalOneZoneBuildings/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "TwoIdenticalOneZoneBuildings.root.TwoIdenticalOneZoneBuildings" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)