(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones1 (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 3600.000000 - tolerance : 1e-06 - stepSize : 1.44 LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Using pre-compiled FMU /tmp/tmpsmeof3ue/FMUZoneAdapterZones1-75kihuby/temp/0001_FMUZoneAdapterZones1/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/src/ThermalZones/EnergyPlus/FMUs/Zones1.fmu LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_13_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones1/run_OMSimulator-cs-euler/spawn-FMUZoneAdapterZones1/EnergyPlus.fmu. It will not be converted to SI units. LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Warning from EnergyPlus: "*** Test warning written by Zones1.core.&##10;" info: Result file: Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable FMUZoneAdapterZones1.fmuZonCor.epwName will not be stored in the result file, because the signal type is not supported info: Variable FMUZoneAdapterZones1.fmuZonCor.fmuName will not be stored in the result file, because the signal type is not supported info: Variable FMUZoneAdapterZones1.fmuZonCor.idfName will not be stored in the result file, because the signal type is not supported info: Variable FMUZoneAdapterZones1.fmuZonCor.zoneName will not be stored in the result file, because the signal type is not supported LOG_STDOUT | info | 60.480 FMUZoneAdapterZones1.building: Error from EnergyPlus: Current time 6.0480000000000004E+01 is after next time event 6.0000000000000000E+01. Consider to change option 2.2204460492503131E-14. LOG_ASSERT | debug | 60.480 FMUZoneAdapterZones1.fmuZonCor: Failed to enter event mode in SpawnUtil.c, returned status is Error. error: [fmi2logger] [fmi2Error] FMUZoneAdapterZones1/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | debug | FMU is in unexpected mode in do_event_iteration at t=60.48, modelicaInstance = FMUZoneAdapterZones1.fmuZonCor, mode = continuous. Contact support. error: [fmi2logger] [fmi2Error] FMUZoneAdapterZones1/logFmi2Call: internalEventUpdate: terminated by an assertion. info: 0 warnings info: 2 errors