Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_13_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatPumpGroupAirToWater.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001335/0.001335, allocations: 108.3 kB / 19.73 MB, free: 416 kB / 13.93 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.00178/0.00178, allocations: 213.4 kB / 23.02 MB, free: 2.953 MB / 13.93 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.9747/0.9747, allocations: 230.6 MB / 256.8 MB, free: 9.578 MB / 202.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/package.mo): time 2.055/2.055, allocations: 0.505 GB / 0.8109 GB, free: 2.348 MB / 0.6511 GB " [Timeout remaining time 177] Using package Buildings with version 13.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: setCommandLineOptions("--fmiFlags=s:cvode") Running command: "" <> buildModelFMU(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatPumpGroupAirToWater,fileNamePrefix="Buildings_13_Buildings_Templates_Plants_HeatPumps_Components_Validation_HeatPumpGroupAirToWater",fmuType="me_cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatPumpGroupAirToWater,fileNamePrefix="Buildings_13_Buildings_Templates_Plants_HeatPumps_Components_Validation_HeatPumpGroupAirToWater",fmuType="me_cs",version="2.0",platforms={"static"}) [Timeout 300] "Notification: Performance of FrontEnd - loaded program: time 0.001822/0.001822, allocations: 75.88 kB / 1.179 GB, free: 9.82 MB / 0.9636 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.763/0.7648, allocations: 180.1 MB / 1.355 GB, free: 0.793 MB / 1.026 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Interfaces/PartialController.mo:32:3-39:83:writable] Warning: Parameter ctlPlaAwNrv.nAirHan has no value, and is fixed during initialization (fixed=true), using available start value (start=0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Interfaces/PartialController.mo:40:3-47:83:writable] Warning: Parameter ctlPlaAwNrv.nEquZon has no value, and is fixed during initialization (fixed=true), using available start value (start=0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Interfaces/PartialController.mo:32:3-39:83:writable] Warning: Parameter ctlPlaAw.nAirHan has no value, and is fixed during initialization (fixed=true), using available start value (start=0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Interfaces/PartialController.mo:40:3-47:83:writable] Warning: Parameter ctlPlaAw.nEquZon has no value, and is fixed during initialization (fixed=true), using available start value (start=0) as default value. Notification: Performance of NFInst.instantiate(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatPumpGroupAirToWater): time 1.074/1.838, allocations: 432.5 MB / 1.777 GB, free: 34.27 MB / 1.385 GB Notification: Performance of NFInst.instExpressions: time 0.07984/1.918, allocations: 68.78 MB / 1.844 GB, free: 33.21 MB / 1.385 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01779/1.936, allocations: 0.5769 MB / 1.845 GB, free: 33.21 MB / 1.385 GB Notification: Performance of NFTyping.typeComponents: time 0.02307/1.959, allocations: 6.754 MB / 1.851 GB, free: 32.88 MB / 1.385 GB Notification: Performance of NFTyping.typeBindings: time 0.05932/2.018, allocations: 13.89 MB / 1.865 GB, free: 29.32 MB / 1.385 GB Notification: Performance of NFTyping.typeClassSections: time 0.01926/2.038, allocations: 9.954 MB / 1.875 GB, free: 24.77 MB / 1.385 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:17:3-24:112:writable] Warning: Parameter datCtlPlaAwNrv.THeaWatSupSet_min has no value, and is fixed during initialization (fixed=true), using available start value (start=25.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:31:3-37:112:writable] Warning: Parameter datCtlPlaAwNrv.VHeaWatHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.1) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:46:3-51:112:writable] Warning: Parameter datCtlPlaAwNrv.capHeaHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:61:3-68:98:writable] Warning: Parameter datCtlPlaAwNrv.VHeaWatSec_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.01) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:96:3-104:45:writable] Warning: Parameter datCtlPlaAwNrv.dpHeaWatLocSet_max has no value, and is fixed during initialization (fixed=true), using available start value (start=1e5) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:105:3-115:37:writable] Warning: Parameter datCtlPlaAwNrv.yPumHeaWatPriSet has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:137:3-143:31:writable] Warning: Parameter datCtlPlaAwNrv.TChiWatSup_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=Buildings.Templates.Data.Defaults.TChiWatSup) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:144:3-150:112:writable] Warning: Parameter datCtlPlaAwNrv.TChiWatSupSet_max has no value, and is fixed during initialization (fixed=true), using available start value (start=15.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:157:3-163:112:writable] Warning: Parameter datCtlPlaAwNrv.VChiWatHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.1) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:172:3-177:112:writable] Warning: Parameter datCtlPlaAwNrv.capCooHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:187:3-194:98:writable] Warning: Parameter datCtlPlaAwNrv.VChiWatSec_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.01) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:226:3-234:45:writable] Warning: Parameter datCtlPlaAwNrv.dpChiWatLocSet_max has no value, and is fixed during initialization (fixed=true), using available start value (start=1e5) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:235:3-244:37:writable] Warning: Parameter datCtlPlaAwNrv.yPumChiWatPriSet has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:303:3-309:87:writable] Warning: Parameter datCtlPlaAwNrv.TChiWatSupHrc_min has no value, and is fixed during initialization (fixed=true), using available start value (start=4.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:310:3-316:87:writable] Warning: Parameter datCtlPlaAwNrv.THeaWatSupHrc_max has no value, and is fixed during initialization (fixed=true), using available start value (start=60.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:317:3-322:87:writable] Warning: Parameter datCtlPlaAwNrv.COPHeaHrc_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=2.8) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:323:3-328:87:writable] Warning: Parameter datCtlPlaAwNrv.capCooHrc_min has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:329:3-334:87:writable] Warning: Parameter datCtlPlaAwNrv.capHeaHrc_min has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:17:3-24:112:writable] Warning: Parameter datCtlPlaAw.THeaWatSupSet_min has no value, and is fixed during initialization (fixed=true), using available start value (start=25.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:31:3-37:112:writable] Warning: Parameter datCtlPlaAw.VHeaWatHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.1) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:46:3-51:112:writable] Warning: Parameter datCtlPlaAw.capHeaHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:61:3-68:98:writable] Warning: Parameter datCtlPlaAw.VHeaWatSec_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.01) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:96:3-104:45:writable] Warning: Parameter datCtlPlaAw.dpHeaWatLocSet_max has no value, and is fixed during initialization (fixed=true), using available start value (start=1e5) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:105:3-115:37:writable] Warning: Parameter datCtlPlaAw.yPumHeaWatPriSet has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:144:3-150:112:writable] Warning: Parameter datCtlPlaAw.TChiWatSupSet_max has no value, and is fixed during initialization (fixed=true), using available start value (start=15.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:157:3-163:112:writable] Warning: Parameter datCtlPlaAw.VChiWatHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.1) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:172:3-177:112:writable] Warning: Parameter datCtlPlaAw.capCooHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:187:3-194:98:writable] Warning: Parameter datCtlPlaAw.VChiWatSec_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.01) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:226:3-234:45:writable] Warning: Parameter datCtlPlaAw.dpChiWatLocSet_max has no value, and is fixed during initialization (fixed=true), using available start value (start=1e5) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:235:3-244:37:writable] Warning: Parameter datCtlPlaAw.yPumChiWatPriSet has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:303:3-309:87:writable] Warning: Parameter datCtlPlaAw.TChiWatSupHrc_min has no value, and is fixed during initialization (fixed=true), using available start value (start=4.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:310:3-316:87:writable] Warning: Parameter datCtlPlaAw.THeaWatSupHrc_max has no value, and is fixed during initialization (fixed=true), using available start value (start=60.0 + 273.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:317:3-322:87:writable] Warning: Parameter datCtlPlaAw.COPHeaHrc_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=2.8) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:323:3-328:87:writable] Warning: Parameter datCtlPlaAw.capCooHrc_min has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:329:3-334:87:writable] Warning: Parameter datCtlPlaAw.capHeaHrc_min has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:64:3-70:22:writable] Warning: Parameter datHpAwNrv.mChiWatHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:75:3-79:22:writable] Warning: Parameter datHpAwNrv.capCooHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:80:3-85:22:writable] Warning: Parameter datHpAwNrv.TChiWatSupHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=280.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:97:3-103:79:writable] Warning: Parameter datHpAwNrv.mSouWwHeaHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=datHpAwNrv.mHeaWatHp_flow_nominal) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:104:3-109:79:writable] Warning: Parameter datHpAwNrv.dpSouWwHeaHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=Buildings.Templates.Data.Defaults.dpChiWatChi) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:119:3-124:22:writable] Warning: Parameter datHpAwNrv.TSouCooHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=Buildings.Templates.Data.Defaults.TOutHpCoo) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:125:3-131:90:writable] Warning: Parameter datHpAwNrv.mSouWwCooHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=datHpAwNrv.mChiWatHp_flow_nominal) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:97:3-103:79:writable] Warning: Parameter datHpAw.mSouWwHeaHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=datHpAw.mHeaWatHp_flow_nominal) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:104:3-109:79:writable] Warning: Parameter datHpAw.dpSouWwHeaHp_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=Buildings.Templates.Data.Defaults.dpChiWatChi) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Data/HeatPumpGroup.mo:125:3-131:90:writable] Warning: Parameter datHpAw.mSouWwCooHp_flow_nominal has no value, and is fixed during initialization (fixed=true), using available start value (start=datHpAw.mChiWatHp_flow_nominal) as default value. Notification: Performance of NFFlatten.flatten: time 0.07826/2.116, allocations: 75.58 MB / 1.949 GB, free: 12.86 MB / 1.417 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Templates/Plants/HeatPumps/Components/Validation/HeatPumpGroupAirToWater.mo:342:3-343:80:writable] Error: Cannot connect expandable connector busHp with non-expandable connector busPla.hp. Notification: Performance of FrontEnd: time 0.01281/2.129, allocations: 7.54 MB / 1.956 GB, free: 5.219 MB / 1.417 GB " [Timeout remaining time 298] [Calling sys.exit(0), Time elapsed: 6.6765836756676435]