(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Fluid_FixedResistances_BuriedPipes_Validation_GroundCouplingAIT_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=603900 --stepSize=900 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_Fluid_FixedResistances_BuriedPipes_Validation_GroundCouplingAIT_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.Fluid.FixedResistances.BuriedPipes.Validation.GroundCouplingAIT (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 603900.000000 - tolerance : 1e-06 - stepSize : 900 LOG_STDOUT | info | ... loading "dat" from "/tmp/tmp6rh8xvpf/GroundCouplingAIT-orimglk7/temp/0001_GroundCouplingAIT/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/Fluid/FixedResistances/Validation/PlugFlowPipes/PipeDataAIT151218.mos" info: Result file: Buildings_13_Buildings_Fluid_FixedResistances_BuriedPipes_Validation_GroundCouplingAIT_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter GroundCouplingAIT.DataReader.delimiter will not be stored in the result file, because the signal type is not supported info: Variable GroundCouplingAIT.DataReader.fileName will not be stored in the result file, because the signal type is not supported info: Parameter GroundCouplingAIT.DataReader.tableName will not be stored in the result file, because the signal type is not supported info: Variable GroundCouplingAIT.pipeDataAIT151218.filNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 900.000000 | | | | ((noEvent(pip0.vol_a.dynBal.medium.T <= 403.15))) --> "In GroundCouplingAIT.pip0.vol_a.dynBal.medium: Temperature T = 230925 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] GroundCouplingAIT/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 1800.000000 | | | | ((noEvent(pip0.vol_a.dynBal.medium.T <= 403.15))) --> "In GroundCouplingAIT.pip0.vol_a.dynBal.medium: Temperature T = 230925 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] GroundCouplingAIT/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "GroundCouplingAIT.root.GroundCouplingAIT" LOG_STDOUT | error | x got reinitialized during an event at time 1800.000000. OpenModelica can't handle that. error: [fmi2logger] [fmi2Error] GroundCouplingAIT/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable switch1.u2 Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 5 errors