(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Fluid_CHPs_Validation_ThermalFollowing_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=10000 --stepSize=4 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_Fluid_CHPs_Validation_ThermalFollowing_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.Fluid.CHPs.Validation.ThermalFollowing (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 10000.000000 - tolerance : 1e-06 - stepSize : 4 LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmp4ugabc7j/ThermalFollowing-639vyo4c/temp/0001_ThermalFollowing/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/Fluid/CHPs/Validation/MicroCogeneration.mos" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((theFolNeg.opeMod.assWatMas.nand.y)) --> "Water flow rate is lower than the minimum!" info: Result file: Buildings_13_Buildings_Fluid_CHPs_Validation_ThermalFollowing_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter ThermalFollowing.avaSig.combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter ThermalFollowing.avaSig.combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter ThermalFollowing.avaSig.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable ThermalFollowing.theFol.assWatTem.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable ThermalFollowing.theFol.fil.assPow.assMesDP.message will not be stored in the result file, because the signal type is not supported info: Variable ThermalFollowing.theFol.fil.assPow.assMesP.message will not be stored in the result file, because the signal type is not supported info: Variable ThermalFollowing.theFolNeg.assWatTem.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable ThermalFollowing.theFolNeg.fil.assPow.assMesDP.message will not be stored in the result file, because the signal type is not supported info: Variable ThermalFollowing.theFolNeg.fil.assPow.assMesP.message will not be stored in the result file, because the signal type is not supported info: Parameter ThermalFollowing.valDat.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter ThermalFollowing.valDat.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16.000000 | | | | ((theFol.fil.assPow.assMesDP.u)) --> "Rate of change in power output is outside boundaries!" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16.000000 | | | | ((not theFol.eneCon.assFue.hys.y)) --> "Rate of change in the fuel mass flow rate is outside boundaries!" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 20.000000 | | | | ((theFolNeg.fil.assPow.assMesDP.u)) --> "Rate of change in power output is outside boundaries!" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 28.000000 | | | | ((not theFol.assWatTem.hys.y)) --> "Water temperature is higher than the maximum!" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 36.000000 | | | | ((noEvent(theFol.vol.dynBal.medium.T <= 403.15))) --> "In ThermalFollowing.theFol.vol.dynBal.medium: Temperature T = 645.197 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] ThermalFollowing/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 36.000000 | | | | ((noEvent(theFol.vol.dynBal.medium.T <= 403.15))) --> "In ThermalFollowing.theFol.vol.dynBal.medium: Temperature T = 645.197 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] ThermalFollowing/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 40.000000 | | | | ((noEvent(theFol.vol.dynBal.medium.T <= 403.15))) --> "In ThermalFollowing.theFol.vol.dynBal.medium: Temperature T = 645.197 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] ThermalFollowing/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "ThermalFollowing.root.ThermalFollowing" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:63:5-64:122:writable] | | | | The following assertion has been violated at time 40.000000 | | | | ((noEvent(theFol.vol.dynBal.medium.T >= 272.15))) --> "In ThermalFollowing.theFol.vol.dynBal.medium: Temperature T = -216.229 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] ThermalFollowing/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable theFolNeg.theFol Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 6 errors