(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Examples_Tutorial_Boiler_System6_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=172800 --stepSize=69.12 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_Examples_Tutorial_Boiler_System6_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.Examples.Tutorial.Boiler.System6 (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 172800.000000 - tolerance : 1e-06 - stepSize : 69.12 info: Result file: Buildings_13_Buildings_Examples_Tutorial_Boiler_System6_OMSimulator-cs-euler_res.mat (bufferSize=10) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 69.120000 | | | | (((-pumRad.dp) <= pumRad.dpMax)) --> "In System6.pumRad: Model operates with head -dp = 78051.4 Pa, | | | | exceeding the pressure allowed by the parameter System6.pumRad.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] System6/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated at time 138.240000 | | | | (((-pumBoi.dp) <= pumBoi.dpMax)) --> "In System6.pumBoi: Model operates with head -dp = 133039 Pa, | | | | exceeding the pressure allowed by the parameter System6.pumBoi.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] System6/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "System6.root.System6" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Water.mo:66:5-67:122:writable] | | | | The following assertion has been violated at time 138.240000 | | | | ((noEvent(pumBoi.vol.dynBal.medium.T <= 403.15))) --> "In System6.pumBoi.vol.dynBal.medium: Temperature T = 1876.42 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] [fmi2Error] System6/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable not3.y Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 5 errors