(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Examples_Steam_SingleBoiler_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Examples_Steam_SingleBoiler_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.DHC.Examples.Steam.SingleBoiler (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-06 - stepSize : 34.56 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/DHC/Loads/Steam/BaseClasses/ValveSelfActing.mo:42:3-44:88:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((bld[3].prv.dpSet.u2 > 0.0)) --> "pb_nominal is set higher than the upstream pressure in SingleBoiler.bld[3].prv, which results in a negative pressure drop. | | | | This is not typical of real systems and should be verified." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/DHC/Loads/Steam/BaseClasses/ValveSelfActing.mo:42:3-44:88:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((bld[2].prv.dpSet.u2 > 0.0)) --> "pb_nominal is set higher than the upstream pressure in SingleBoiler.bld[2].prv, which results in a negative pressure drop. | | | | This is not typical of real systems and should be verified." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/DHC/Loads/Steam/BaseClasses/ValveSelfActing.mo:42:3-44:88:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((bld[1].prv.dpSet.u2 > 0.0)) --> "pb_nominal is set higher than the upstream pressure in SingleBoiler.bld[1].prv, which results in a negative pressure drop. | | | | This is not typical of real systems and should be verified." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Steam.mo:26:5-26:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bld[1].sta_a.T >= 1.0 and bld[1].sta_a.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= bld[1].sta_a.T <= 1e4, has value: -918.506" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Steam.mo:26:5-26:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bld[2].sta_a.T >= 1.0 and bld[2].sta_a.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= bld[2].sta_a.T <= 1e4, has value: -918.506" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Media/Steam.mo:26:5-26:42:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bld[3].sta_a.T >= 1.0 and bld[3].sta_a.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= bld[3].sta_a.T <= 1e4, has value: -918.506" info: Result file: Buildings_13_Buildings_DHC_Examples_Steam_SingleBoiler_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter SingleBoiler.bld[1].QHea.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter SingleBoiler.bld[2].QHea.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter SingleBoiler.bld[3].QHea.delimiter will not be stored in the result file, because the signal type is not supported info: Variable SingleBoiler.bld[1].QHea.fileName will not be stored in the result file, because the signal type is not supported info: Variable SingleBoiler.bld[2].QHea.fileName will not be stored in the result file, because the signal type is not supported info: Variable SingleBoiler.bld[3].QHea.fileName will not be stored in the result file, because the signal type is not supported info: Variable SingleBoiler.bld[1].QHea.tableName will not be stored in the result file, because the signal type is not supported info: Variable SingleBoiler.bld[2].QHea.tableName will not be stored in the result file, because the signal type is not supported info: Variable SingleBoiler.bld[3].QHea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter SingleBoiler.bld[1].fileName will not be stored in the result file, because the signal type is not supported info: Parameter SingleBoiler.bld[2].fileName will not be stored in the result file, because the signal type is not supported info: Parameter SingleBoiler.bld[3].fileName will not be stored in the result file, because the signal type is not supported info: Parameter SingleBoiler.bld[1].tableName will not be stored in the result file, because the signal type is not supported info: Parameter SingleBoiler.bld[2].tableName will not be stored in the result file, because the signal type is not supported info: Parameter SingleBoiler.bld[3].tableName will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] SingleBoiler/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Media/Water/IF97_Utilities.mo:1912: IF97 medium function g2: the temperature (= -437.154 K) is lower than 273.15 K! Segmentation fault (core dumped)