(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer_OMSimulator-cs-euler_fmu --startTime=1.87488e+07 --stopTime=1.93536e+07 --stepSize=240.669 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer (co-simulation) - fmiVersion: 2.0 - startTime : 18748800.000000 - stopTime : 19353600.000000 - tolerance : 1e-06 - stepSize : 240.669 EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.14 12:07 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 08/06/2006 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output OneZoneOneOutputVariableSummer.equEle.y has in Modelica the unit 1. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 18748800.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" info: Result file: ../Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter OneZoneOneOutputVariableSummer.equEle.key will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariableSummer.equEle.name will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneOneOutputVariableSummer.zon.zoneName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 18749522.007000 | | | | ((noEvent(zon.vol.medium.T >= 200.0))) --> "In OneZoneOneOutputVariableSummer.zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." error: [fmi2logger] [fmi2Error] OneZoneOneOutputVariableSummer/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Media/Air.mo:149:5-150:57:writable] | | | | The following assertion has been violated at time 18749522.007000 | | | | ((noEvent(zon.vol.medium.T >= 200.0))) --> "In OneZoneOneOutputVariableSummer.zon.vol.medium: Temperature T exceeded its minimum allowed value of -73.15 degC (200 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." error: [fmi2logger] [fmi2Error] OneZoneOneOutputVariableSummer/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Media/Air.mo:146:5-147:72:writable] | | | | The following assertion has been violated at time 18749762.676000 | | | | ((noEvent(zon.vol.medium.Xi[1] >= -1e-5) and noEvent(zon.vol.medium.Xi[1] <= 1.00001))) --> "Mass fraction X[1] = -1.38135 of substance water | | | | of medium "Buildings.Media.Air" is not in the range 0..1" error: [fmi2logger] [fmi2Error] OneZoneOneOutputVariableSummer/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "OneZoneOneOutputVariableSummer.root.OneZoneOneOutputVariableSummer" LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer/577.fmutmp/sources/Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer_functions.c:1054: Invalid root: (-75.278)^(-1.5) error: [fmi2logger] [fmi2Error] OneZoneOneOutputVariableSummer/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable zon.use_C_flow Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)