(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.HeatPumpRadiantHeatingGroundHeatTransfer_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_HeatPumpRadiantHeatingGroundHeatTransfer_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=172800 --stepSize=69.12 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_HeatPumpRadiantHeatingGroundHeatTransfer_OMSimulator-cs-euler.fmu) LOG_STDOUT | info | Using sparse solver for linear system 30, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. LOG_STDOUT | info | Using sparse solver for linear system 64, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.HeatPumpRadiantHeatingGroundHeatTransfer (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 172800.000000 - tolerance : 1e-06 - stepSize : 69.12 EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.14 12:06 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_ASSERT | debug | Division by zero 114.55 * T / p in function context LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | Division by zero 114.55 * T / p in function context LOG_ASSERT | debug | Division by zero 345.25 / T in function context LOG_ASSERT | debug | Division by zero 345.25 / T in function context LOG_ASSERT | debug | Solving non-linear system 2186 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | error | Failed to solve the initialization problem with global homotopy with equidistant step size. LOG_ASSERT | debug | Unable to solve initialization problem. error: [fmi2logger] [fmi2Error] HeatPumpRadiantHeatingGroundHeatTransfer/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_exitInitializationMode failed for FMU "HeatPumpRadiantHeatingGroundHeatTransfer.root.HeatPumpRadiantHeatingGroundHeatTransfer" Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.16sec EnergyPlus Completed Successfully. error: [initialize] Initialization of system "HeatPumpRadiantHeatingGroundHeatTransfer.root" failed Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 175, in _runFMU fmu.initialize() ~~~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 887, in initialize raise RuntimeError(f"Failed to initialize model: {status}") RuntimeError: Failed to initialize model: Status.error info: 0 warnings info: 3 errors