(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage_OMSimulator-cs-euler_fmu --startTime=1.0368e+07 --stopTime=1.07136e+07 --stepSize=138.24 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage (co-simulation) - fmiVersion: 2.0 - startTime : 10368000.000000 - stopTime : 10713600.000000 - tolerance : 1e-06 - stepSize : 138.24 LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmpq52kcyo8/BigCollectorInstallationWithStorage-207rlgrq/temp/0001_BigCollectorInstallationWithStorage/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in BigCollectorInstallationWithStorage.pump1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in BigCollectorInstallationWithStorage.pump2: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((not senTem1.warnAboutOnePortConnection)) --> "Sensor BigCollectorInstallationWithStorage.senTem1 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. | | | | See BuildingSystems.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in BigCollectorInstallationWithStorage.senTem1." info: Result file: BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter BigCollectorInstallationWithStorage.weatherData.weatherData.datRea.delimiter will not be stored in the result file, because the signal type is not supported info: Variable BigCollectorInstallationWithStorage.weatherData.weatherData.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable BigCollectorInstallationWithStorage.weatherData.weatherData.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter BigCollectorInstallationWithStorage.weatherData.weatherData.info will not be stored in the result file, because the signal type is not supported info: Variable BigCollectorInstallationWithStorage.weatherData.weatherData.tabNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Media/Water.mo:65:5-66:128:writable] | | | | The following assertion has been violated at time 10368276.480000 | | | | ((noEvent(storage.vol_bot.dynBal.medium.T <= 403.15))) --> "In BigCollectorInstallationWithStorage.storage.vol_bot.dynBal.medium: Temperature T = 1495.84 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "BuildingSystems.Media.Water"." error: [fmi2logger] [fmi2Error] BigCollectorInstallationWithStorage/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Media/Water.mo:65:5-66:128:writable] | | | | The following assertion has been violated at time 10368276.480000 | | | | ((noEvent(storage.vol_bot.dynBal.medium.T <= 403.15))) --> "In BigCollectorInstallationWithStorage.storage.vol_bot.dynBal.medium: Temperature T = 1495.84 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "BuildingSystems.Media.Water"." error: [fmi2logger] [fmi2Error] BigCollectorInstallationWithStorage/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Media/Water.mo:65:5-66:128:writable] | | | | The following assertion has been violated at time 10368414.720000 | | | | ((noEvent(pump2.vol.dynBal.medium.T <= 403.15))) --> "In BigCollectorInstallationWithStorage.pump2.vol.dynBal.medium: Temperature T = 79494.9 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "BuildingSystems.Media.Water"." error: [fmi2logger] [fmi2Error] BigCollectorInstallationWithStorage/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "BigCollectorInstallationWithStorage.root.BigCollectorInstallationWithStorage" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 10368414.720000 | | | | (((-pump2.dp) <= pump2.dpMax)) --> "In BigCollectorInstallationWithStorage.pump2: Model operates with head -dp = 6.6781e+09 Pa, | | | | exceeding the pressure allowed by the parameter BigCollectorInstallationWithStorage.pump2.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] BigCollectorInstallationWithStorage/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable booleanControl2.y Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 6 errors