(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem1_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=3.1536e+07 --stepSize=12614.4 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem1_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : BuildingSystems.Applications.SolarThermalSystems.SolarThermalSystem1 (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 31536000.000000 - tolerance : 1e-06 - stepSize : 12614.4 LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmplbsa77ad/SolarThermalSystem1-i5adasnp/temp/0001_SolarThermalSystem1/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/weather/Egypt_ElGouna.txt" info: Result file: BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem1_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter SolarThermalSystem1.weatherData.weatherData.datRea.delimiter will not be stored in the result file, because the signal type is not supported info: Variable SolarThermalSystem1.weatherData.weatherData.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable SolarThermalSystem1.weatherData.weatherData.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter SolarThermalSystem1.weatherData.weatherData.info will not be stored in the result file, because the signal type is not supported info: Variable SolarThermalSystem1.weatherData.weatherData.tabNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Media/Water.mo:65:5-66:128:writable] | | | | The following assertion has been violated at time 37843.200000 | | | | ((noEvent(storage.vol[1].dynBal.medium.T <= 403.15))) --> "In SolarThermalSystem1.storage.vol[1].dynBal.medium: Temperature T = 1116.51 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "BuildingSystems.Media.Water"." error: [fmi2logger] [fmi2Error] SolarThermalSystem1/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Media/Water.mo:65:5-66:128:writable] | | | | The following assertion has been violated at time 37843.200000 | | | | ((noEvent(storage.vol[1].dynBal.medium.T <= 403.15))) --> "In SolarThermalSystem1.storage.vol[1].dynBal.medium: Temperature T = 1116.51 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "BuildingSystems.Media.Water"." error: [fmi2logger] [fmi2Error] SolarThermalSystem1/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Media/Water.mo:62:5-63:128:writable] | | | | The following assertion has been violated at time 50457.600000 | | | | ((noEvent(storage.vol_bot.dynBal.medium.T >= 272.15))) --> "In SolarThermalSystem1.storage.vol_bot.dynBal.medium: Temperature T = -732.562 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "BuildingSystems.Media.Water"." error: [fmi2logger] [fmi2Error] SolarThermalSystem1/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "SolarThermalSystem1.root.SolarThermalSystem1" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Media/Water.mo:62:5-63:128:writable] | | | | The following assertion has been violated at time 50457.600000 | | | | ((noEvent(storage.vol_top.dynBal.medium.T >= 272.15))) --> "In SolarThermalSystem1.storage.vol_top.dynBal.medium: Temperature T = 221.886 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "BuildingSystems.Media.Water"." error: [fmi2logger] [fmi2Error] SolarThermalSystem1/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable booleanToReal.u Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 6 errors