(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_Airflow_Multizone_Examples_CO2TransportStep_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildSysPro_BuildSysPro_IBPSA_Airflow_Multizone_Examples_CO2TransportStep_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : BuildSysPro.IBPSA.Airflow.Multizone.Examples.CO2TransportStep (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-06 - stepSize : 34.56 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenTop.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenTop can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`. | | | | See IBPSA.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenTop." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenWes.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenWes can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`. | | | | See IBPSA.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenWes." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenEas.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenEas can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`. | | | | See IBPSA.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenEas." info: Result file: BuildSysPro_BuildSysPro_IBPSA_Airflow_Multizone_Examples_CO2TransportStep_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable CO2TransportStep.CO2SenEas.substanceName will not be stored in the result file, because the signal type is not supported info: Variable CO2TransportStep.CO2SenTop.substanceName will not be stored in the result file, because the signal type is not supported info: Variable CO2TransportStep.CO2SenWes.substanceName will not be stored in the result file, because the signal type is not supported info: Variable CO2TransportStep.sou.substanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Media/Air.mo:143:5-144:68:writable] | | | | The following assertion has been violated at time 69.120000 | | | | ((noEvent(volEas.dynBal.medium.Xi[1] >= -1e-5) and noEvent(volEas.dynBal.medium.Xi[1] <= 1.00001))) --> "Mass fraction X[1] = -0.0400192 of substance water | | | | of medium "IBPSA.Media.Air" is not in the range 0..1" error: [fmi2logger] [fmi2Error] CO2TransportStep/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "CO2TransportStep.root.CO2TransportStep" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Media/Air.mo:143:5-144:68:writable] | | | | The following assertion has been violated at time 69.120000 | | | | ((noEvent(volEas.dynBal.medium.Xi[1] >= -1e-5) and noEvent(volEas.dynBal.medium.Xi[1] <= 1.00001))) --> "Mass fraction X[1] = -0.0400192 of substance water | | | | of medium "IBPSA.Media.Air" is not in the range 0..1" error: [fmi2logger] [fmi2Error] CO2TransportStep/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable volWes.use_C_flow Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 4 errors