(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=7200 --stepSize=2.88 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : AixLib.Systems.ModularAHU.Examples.GenericAHU (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 7200.000000 - tolerance : 1e-06 - stepSize : 2.88 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GenericAHU.genericAHU.fanSup: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GenericAHU.genericAHU.fanRet: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100:3-100:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((genericAHU.preheater.hydraulicModule.PumpInterface.pump.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.preheater.hydraulicModule.PumpInterface.pump.eta, has value: -2.89462e-12" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((genericAHU.preheater.hydraulicModule.PumpInterface.pump.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.preheater.hydraulicModule.PumpInterface.pump.heaDis.etaHyd, has value: -4.34644e-09" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((genericAHU.preheater.hydraulicModule.PumpInterface.pump.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.preheater.hydraulicModule.PumpInterface.pump.eff.yMot, has value: -3.38214e-14" info: Result file: AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable GenericAHU.genericAHU.cooler.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.cooler.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.cooler.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.cooler.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.cooler.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.cooler.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.cooler.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter GenericAHU.genericAHU.cooler.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.heater.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.heater.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.heater.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.heater.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.heater.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.heater.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.heater.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter GenericAHU.genericAHU.heater.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.preheater.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.preheater.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.preheater.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.preheater.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.preheater.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.preheater.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable GenericAHU.genericAHU.preheater.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter GenericAHU.genericAHU.preheater.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Air.mo:146:5-147:69:writable] | | | | The following assertion has been violated at time 5.760000 | | | | ((noEvent(genericAHU.fanRet.vol.dynBal.medium.Xi[1] >= -1e-5) and noEvent(genericAHU.fanRet.vol.dynBal.medium.Xi[1] <= 1.00001))) --> "Mass fraction X[1] = -0.0346376 of substance water | | | | of medium "AixLib.Media.Air" is not in the range 0..1" error: [fmi2logger] [fmi2Error] GenericAHU/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "GenericAHU.root.GenericAHU" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Air.mo:154:3-154:145:writable] | | | | The following assertion has been violated at time 5.760000 | | | | ((noEvent(genericAHU.fanRet.vol.dynBal.medium.p >= 0.0))) --> "Pressure (= -350965 Pa) of medium "AixLib.Media.Air" is negative | | | | (Temperature = 519.601 K)" error: [fmi2logger] [fmi2Error] GenericAHU/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable genericAHU.usePreheater Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 4 errors