(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_Systems_HydraulicModules_Examples_ThrottlePump_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=600 --stepSize=0.24 --mode=cs --timeout=240 --tolerance=1e-06 ../AixLib_AixLib_Systems_HydraulicModules_Examples_ThrottlePump_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : AixLib.Systems.HydraulicModules.Examples.ThrottlePump (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 600.000000 - tolerance : 1e-06 - stepSize : 0.24 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100:3-100:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ThrottlePump.PumpInterface.pump.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.eta, has value: -8.76995e-44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ThrottlePump.PumpInterface.pump.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.heaDis.etaHyd, has value: -7.35443e-41" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ThrottlePump.PumpInterface.pump.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.eff.yMot, has value: -9.78277e-46" info: Result file: AixLib_AixLib_Systems_HydraulicModules_Examples_ThrottlePump_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable ThrottlePump.ThrottlePump.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ThrottlePump.ThrottlePump.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ThrottlePump.ThrottlePump.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ThrottlePump.ThrottlePump.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable ThrottlePump.ThrottlePump.pipeModel will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Water.mo:63:5-64:119:writable] | | | | The following assertion has been violated at time 1.680000 | | | | ((noEvent(ThrottlePump.pipe1.simplePipe.vol[1].dynBal.medium.T >= 272.15))) --> "In ThrottlePump.ThrottlePump.pipe1.simplePipe.vol[1].dynBal.medium: Temperature T = 253.93 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "AixLib.Media.Water"." error: [fmi2logger] [fmi2Error] ThrottlePump/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Water.mo:63:5-64:119:writable] | | | | The following assertion has been violated at time 1.920000 | | | | ((noEvent(ThrottlePump.pipe4.simplePipe.vol[3].dynBal.medium.T >= 272.15))) --> "In ThrottlePump.ThrottlePump.pipe4.simplePipe.vol[3].dynBal.medium: Temperature T = 254.217 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "AixLib.Media.Water"." error: [fmi2logger] [fmi2Error] ThrottlePump/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "ThrottlePump.root.ThrottlePump" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Media/Water.mo:66:5-67:119:writable] | | | | The following assertion has been violated at time 1.920000 | | | | ((noEvent(ThrottlePump.pipe4.simplePipe.vol[3].dynBal.medium.T <= 403.15))) --> "In ThrottlePump.ThrottlePump.pipe4.simplePipe.vol[3].dynBal.medium: Temperature T = 3115.68 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "AixLib.Media.Water"." error: [fmi2logger] [fmi2Error] ThrottlePump/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable pumpOn.y Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 5 errors