Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr AixLib_AixLib.Obsolete.Year2021.Electrical.PVSystem.Examples.ExamplePV.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.2.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.2.0/package.mo): time 0.0461/0.0461, allocations: 12.17 MB / 31.02 MB, free: 0.9961 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0009151/0.0009151, allocations: 120.6 kB / 37.24 MB, free: 1.336 MB / 24.77 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001001/0.001001, allocations: 214.4 kB / 43.58 MB, free: 3.273 MB / 33.03 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.9529/0.9529, allocations: 230.6 MB / 280.4 MB, free: 7.133 MB / 202.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF 0.4.5/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF 0.4.5/package.mo): time 0.004473/0.004473, allocations: 1.088 MB / 340.9 MB, free: 11.68 MB / 266.7 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/package.mo): time 1.679/1.679, allocations: 353.8 MB / 0.7367 GB, free: 23.36 MB / 0.5262 GB " [Timeout remaining time 178] Using package AixLib with version 3.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/package.mo) Using package SDF with version 0.4.5 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF 0.4.5/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Using package Modelica_DeviceDrivers with version 2.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.2.0/package.mo) Running command: setCommandLineOptions("--fmiFlags=s:cvode") Running command: "" <> buildModelFMU(AixLib.Obsolete.Year2021.Electrical.PVSystem.Examples.ExamplePV,fileNamePrefix="AixLib_AixLib_Obsolete_Year2021_Electrical_PVSystem_Examples_ExamplePV",fmuType="me_cs",version="2.0",platforms={"static"}) "" <> buildModelFMU(AixLib.Obsolete.Year2021.Electrical.PVSystem.Examples.ExamplePV,fileNamePrefix="AixLib_AixLib_Obsolete_Year2021_Electrical_PVSystem_Examples_ExamplePV",fmuType="me_cs",version="2.0",platforms={"static"}) [Timeout 660] "Notification: SDF requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Warning: Requested package SDF of version 0.4.4, but this package was already loaded with version 0.4.5. There are no conversion annotations and 0.4.4 is older than 0.4.5, so the libraries are probably incompatible. Notification: AixLib requested package Modelica_DeviceDrivers of version 2.1.1. Modelica_DeviceDrivers 2.2.0 is used instead which states that it is fully compatible without conversion script needed. Notification: AixLib requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002487/0.002487, allocations: 141.2 kB / 1.019 GB, free: 48.97 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2018/0.2042, allocations: 135.1 MB / 1.151 GB, free: 11.53 MB / 0.823 GB Notification: Performance of NFInst.instantiate(AixLib.Obsolete.Year2021.Electrical.PVSystem.Examples.ExamplePV): time 0.003686/0.2079, allocations: 3.024 MB / 1.154 GB, free: 8.492 MB / 0.823 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Obsolete/Year2021/Electrical/PVSystem.mo:273:9-273:67:writable] Error: Function AixLib.DataBase.SolarElectric.SymphonyEnergySE6M181 not found in scope ExamplePV. Notification: Performance of FrontEnd: time 0.002391/0.2103, allocations: 2.388 MB / 1.156 GB, free: 6.094 MB / 0.823 GB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 4.358516396023333]