(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_AixLib_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=172800 --stepSize=60 --mode=cs --timeout=240 --tolerance=1e-05 ../AixLib_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : AixLib.Fluid.DistrictHeatingCooling.Supplies.Examples.DHCSupplyHeaterCoolerStorage (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 172800.000000 - tolerance : 1e-05 - stepSize : 60 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation1.pumHeaPri.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSupplyHeaterCoolerStorage.substation1.pumHeaPri: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation1.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSupplyHeaterCoolerStorage.substation1.pumCoo: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation2.pumHeaPri.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSupplyHeaterCoolerStorage.substation2.pumHeaPri: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation2.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DHCSupplyHeaterCoolerStorage.substation2.pumCoo: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/FlowControlled_m_flow.mo:87:3-92:58:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | (((-substation1.pumHeaPri.dp) <= substation1.pumHeaPri.dpMax)) --> "In DHCSupplyHeaterCoolerStorage.substation1.pumHeaPri: Model operates with head -dp = 157090 Pa, | | | | exceeding the pressure allowed by the parameter DHCSupplyHeaterCoolerStorage.substation1.pumHeaPri.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] [fmi2Error] DHCSupplyHeaterCoolerStorage/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_exitInitializationMode failed for FMU "DHCSupplyHeaterCoolerStorage.root.DHCSupplyHeaterCoolerStorage" error: [initialize] Initialization of system "DHCSupplyHeaterCoolerStorage.root" failed Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 175, in _runFMU fmu.initialize() ~~~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 887, in initialize raise RuntimeError(f"Failed to initialize model: {status}") RuntimeError: Failed to initialize model: Status.error info: 0 warnings info: 3 errors