(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.IdealHeatingCoolingSummer_Autosizing_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_IdealHeatingCoolingSummer_Autosizing_OMSimulator-cs-cvode_fmu --startTime=1.6848e+07 --stopTime=1.728e+07 --stepSize=172.8 --mode=cs --timeout=240 --tolerance=1e-07 ../Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_IdealHeatingCoolingSummer_Autosizing_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-07 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.IdealHeatingCoolingSummer_Autosizing (co-simulation) - fmiVersion: 2.0 - startTime : 16848000.000000 - stopTime : 17280000.000000 - tolerance : 1e-07 - stepSize : 172.8 EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.14 11:11 Initializing Response Factors Calculating CTFs for "ATTIC NON-RES FLOOR" Calculating CTFs for "ATTIC NON-RES ROOF" Calculating CTFs for "INTERIORFURNISHINGS" Calculating CTFs for "MASS NON-RES EXT WALL" Calculating CTFs for "EXT-SLAB" Calculating CTFs for "INT-WALLS" Initializing Window Optical Properties Initializing Solar Calculations Allocate Solar Module Arrays Initializing Zone and Enclosure Report Variables Initializing Surface (Shading) Report Variables Determining Shadowing Combinations Computing Window Shade Absorption Factors Proceeding with Initializing Solar Calculations Initializing Surfaces Initializing Outdoor environment for Surfaces Setting up Surface Reporting Variables Initializing Temperature and Flux Histories Initializing Window Shading Computing Interior Absorption Factors Computing Interior Diffuse Solar Absorption Factors Initializing Solar Heat Gains Initializing Internal Heat Gains Initializing Interior Solar Distribution Initializing Interior Convection Coefficients Gathering Information for Predefined Reporting Completed Initializing Surface Heat Balance Calculate Outside Surface Heat Balance Calculate Inside Surface Heat Balance Calculate Air Heat Balance Initializing HVAC Warming up Warming up Warming up Warming up Warming up Warming up Performing Zone Sizing Simulation ...for Sizing Period: #1 CHICAGO ANN CLG .4% CONDNS WB=>MDB Warming up Warming up Warming up Warming up Warming up Warming up Performing Zone Sizing Simulation ...for Sizing Period: #2 CHICAGO ANN HTG 99.6% CONDNS DB Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 07/15/2006 for SPAWN-RUNPERIOD info: Result file: ../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.IdealHeatingCoolingSummer_Autosizing_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.att.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.att.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.cor.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.cor.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.eas.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.eas.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.nor.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.nor.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.sou.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.sou.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.sysSizCor.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.sysSizPer.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.wes.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter IdealHeatingCoolingSummer_Autosizing.flo.wes.zoneName will not be stored in the result file, because the signal type is not supported info: Variable IdealHeatingCoolingSummer_Autosizing.weaDat.filNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 16853356.800000 | | | | ((noEvent(flo.eas.vol.medium.T <= 423.15))) --> "In IdealHeatingCoolingSummer_Autosizing.flo.eas.vol.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." error: [fmi2logger] [fmi2Error] IdealHeatingCoolingSummer_Autosizing/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "IdealHeatingCoolingSummer_Autosizing.root.IdealHeatingCoolingSummer_Autosizing" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Media/Air.mo:151:5-152:57:writable] | | | | The following assertion has been violated at time 16853356.800000 | | | | ((noEvent(flo.eas.vol.medium.T <= 423.15))) --> "In IdealHeatingCoolingSummer_Autosizing.flo.eas.vol.medium: Temperature T exceeded its maximum allowed value of 150 degC (423.15 Kelvin) | | | | as required from medium model "Buildings.Media.Air"." error: [fmi2logger] [fmi2Error] IdealHeatingCoolingSummer_Autosizing/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable hea[5].conPID.I.trigger Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)