(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones1 (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 3600.000000 - tolerance : 1e-06 - stepSize : 1.44 LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Using pre-compiled FMU /tmp/tmpbb5qzsc1/FMUZoneAdapterZones1-2nts6v1d/temp/0001_FMUZoneAdapterZones1/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Resources/src/ThermalZones/EnergyPlus_24_2_0/FMUs/Zones1.fmu LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones1/run_OMSimulator-cs-cvode/spawn-FMUZoneAdapterZones1/EnergyPlus.fmu. It will not be converted to SI units. info: Result file: Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones1_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable FMUZoneAdapterZones1.fmuZonCor.epwName will not be stored in the result file, because the signal type is not supported info: Variable FMUZoneAdapterZones1.fmuZonCor.fmuName will not be stored in the result file, because the signal type is not supported info: Parameter FMUZoneAdapterZones1.fmuZonCor.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Variable FMUZoneAdapterZones1.fmuZonCor.idfName will not be stored in the result file, because the signal type is not supported info: Variable FMUZoneAdapterZones1.fmuZonCor.zoneName will not be stored in the result file, because the signal type is not supported LOG_STDOUT | info | 60.480 FMUZoneAdapterZones1.building: Error from EnergyPlus: Current time 6.0480000000000004E+01 is after next time event 6.0000000000000000E+01. Consider to change option 2.2204460492503131E-14. LOG_ASSERT | debug | 60.480 FMUZoneAdapterZones1.fmuZonCor: Failed to enter event mode in SpawnUtil.c, returned status is Error. error: [fmi2logger] [fmi2Error] FMUZoneAdapterZones1/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | debug | FMU is in unexpected mode in do_event_iteration at t=60.48, modelicaInstance = FMUZoneAdapterZones1.fmuZonCor, mode = continuous. Contact support. error: [fmi2logger] [fmi2Error] FMUZoneAdapterZones1/logFmi2Call: internalEventUpdate: terminated by an assertion. info: 0 warnings info: 2 errors