(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.Fluid.DataCenters.Racks.Hybrid.Examples.AirRearDoorHexActive_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_Fluid_DataCenters_Racks_Hybrid_Examples_AirRearDoorHexActive_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=7200 --stepSize=2.88 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_latest_Buildings_Fluid_DataCenters_Racks_Hybrid_Examples_AirRearDoorHexActive_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.Fluid.DataCenters.Racks.Hybrid.Examples.AirRearDoorHexActive (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 7200.000000 - tolerance : 1e-06 - stepSize : 2.88 LOG_NLS | error | residualFunc191: Iteration variable `òD$$òDYàfA(ÄXÃòAYÃòD^ÛòDYØòDXÓ¢'` is inf or nan. LOG_ASSERT | debug | residualFunc191 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed during initialization. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((datHal.ports[2].m_flow >= 0.0 and datHal.ports[2].m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= datHal.ports[2].m_flow <= 1e5, has value: -4.51768e-25" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((rac.reaDooHex.fan.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= rac.reaDooHex.fan.eff.yMot, has value: -3.52776e-53" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((rac.reaDooHex.fan.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= rac.reaDooHex.fan.heaDis.etaHyd, has value: -6.54651e-47" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100:3-100:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((rac.reaDooHex.fan.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= rac.reaDooHex.fan.eta, has value: -1.5119e-51" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Media/package.mo:5918:7-5918:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((rac.reaDooHex.reaDooHex.state_b1_inflow.T >= 1.0 and rac.reaDooHex.reaDooHex.state_b1_inflow.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= rac.reaDooHex.reaDooHex.state_b1_inflow.T <= 1e4, has value: 0" info: Result file: ../Buildings_latest_Buildings.Fluid.DataCenters.Racks.Hybrid.Examples.AirRearDoorHexActive_OMSimulator-cs-cvode_res.mat (bufferSize=10) LOG_NLS | error | residualFunc858: Iteration variable `` is inf or nan. LOG_ASSERT | debug | residualFunc858 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 0. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_ASSERT | debug | Solving non-linear system 969 failed at time=0.232861922477197. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Fatal] AirRearDoorHexActive/logStatusFatal: fmi2DoStep: ##CVODE## -8 error occurred at time = 0.194223888532695. error: [fmi2logger] [fmi2Fatal] AirRearDoorHexActive/logStatusFatal: fmi2DoStep: CVODE integrator step failed. error: [stepUntil] fmi2_doStep failed for FMU "AirRearDoorHexActive.root.AirRearDoorHexActive" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 3 errors