(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_OneZoneTwoDifferentOutputVariables_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=432000 --stepSize=172.8 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_OneZoneTwoDifferentOutputVariables_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 432000.000000 - tolerance : 1e-06 - stepSize : 172.8 EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.14 13:01 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output OneZoneTwoDifferentOutputVariables.equEle.y has in Modelica the unit 1. LOG_STDOUT | info | Output OneZoneTwoDifferentOutputVariables.incBeaSou.y has in Modelica the unit W/m2. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" info: Result file: Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_OutputVariable_OneZoneTwoDifferentOutputVariables_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter OneZoneTwoDifferentOutputVariables.equEle.key will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneTwoDifferentOutputVariables.equEle.name will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneTwoDifferentOutputVariables.incBeaSou.key will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneTwoDifferentOutputVariables.incBeaSou.name will not be stored in the result file, because the signal type is not supported info: Parameter OneZoneTwoDifferentOutputVariables.zon.zoneName will not be stored in the result file, because the signal type is not supported Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.29sec EnergyPlus Completed Successfully.