(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersWithBypass_OMSimulator-cs-cvode_fmu --startTime=1.0368e+07 --stopTime=1.05408e+07 --stepSize=69.12 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersWithBypass_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersWithBypass (co-simulation) - fmiVersion: 2.0 - startTime : 10368000.000000 - stopTime : 10540800.000000 - tolerance : 1e-06 - stepSize : 69.12 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 10368000.000000 | | | | ((tow.cooTowSys.dat.PFan_Q_flow_nominal >= -0.1 and tow.cooTowSys.dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= tow.cooTowSys.dat.PFan_Q_flow_nominal <= 0.0, has value: -0.825344" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 10368000.000000 | | | | ((tow.cooTowSys.cooTow[2].dat.PFan_Q_flow_nominal >= -0.1 and tow.cooTowSys.cooTow[2].dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= tow.cooTowSys.cooTow[2].dat.PFan_Q_flow_nominal <= 0.0, has value: -0.825344" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 10368000.000000 | | | | ((tow.cooTowSys.cooTow[2].per.dat.PFan_Q_flow_nominal >= -0.1 and tow.cooTowSys.cooTow[2].per.dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= tow.cooTowSys.cooTow[2].per.dat.PFan_Q_flow_nominal <= 0.0, has value: -0.825344" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 10368000.000000 | | | | ((tow.cooTowSys.cooTow[1].dat.PFan_Q_flow_nominal >= -0.1 and tow.cooTowSys.cooTow[1].dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= tow.cooTowSys.cooTow[1].dat.PFan_Q_flow_nominal <= 0.0, has value: -0.825344" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 10368000.000000 | | | | ((tow.cooTowSys.cooTow[1].per.dat.PFan_Q_flow_nominal >= -0.1 and tow.cooTowSys.cooTow[1].per.dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= tow.cooTowSys.cooTow[1].per.dat.PFan_Q_flow_nominal <= 0.0, has value: -0.825344" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/CoolingTowers/BaseClasses/Merkel.mo:68:3-69:53:writable] | | | | The following assertion has been violated at time 10368000.000000 | | | | ((tow.cooTowSys.cooTow[2].per.FRWat >= 0.0 and tow.cooTowSys.cooTow[2].per.FRWat <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= tow.cooTowSys.cooTow[2].per.FRWat <= 1.0, has value: -7.7639e-34" info: Result file: Buildings_13_Buildings_DHC_Plants_Cooling_Subsystems_Examples_CoolingTowersWithBypass_OMSimulator-cs-cvode_res.mat (bufferSize=10)