(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=345600 --stepSize=138.24 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 345600.000000 - tolerance : 1e-06 - stepSize : 138.24 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/BaseClasses/PartialEffectivenessNTU.mo:112:5-117:36:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pla.hexCoo.Q_flow_nominal / (300.05 - pla.hexCoo.T_a2_nominal) >= 0.0)) --> "In AllElectricCWStorage.pla.hexCoo: Q_flow_nominal is defined with the wrong sign. By convention, a positive value describes a heat flow from Medium1 to Medium2. The parameter T_a1_nominal should then be larger than T_a2_nominal.Future version of this library might enforce this convention and throw an error." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumChiWat.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumChiWat.pum.etaHyd, has value: -4.13886e-41" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumHeaWat.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumHeaWat.pum.etaHyd, has value: -2.48586e-41" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumConWatCon.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatCon.pum.etaHyd, has value: -1.26678e-45" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumConWatEva.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatEva.pum.etaHyd, has value: -5.75022e-41" info: Result file: Buildings_13_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter AllElectricCWStorage.pla.heaPum.heaPum.aleMes.message will not be stored in the result file, because the signal type is not supported LOG_NLS | error | residualFunc14446: Iteration variable `(null)` is inf or nan. LOG_ASSERT | debug | residualFunc14446 failed at time=14400. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 14400. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_NLS | error | residualFunc15311: Iteration variable `(null)` is inf or nan. LOG_ASSERT | debug | residualFunc15311 failed at time=40227.8400000001. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 40227.8. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_NLS | error | residualFunc15311: Iteration variable `(null)` is inf or nan. LOG_ASSERT | debug | residualFunc15311 failed at time=95247.3600000008. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 95247.4. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_13_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage/259.fmutmp/sources/gc/memory_pool.c:100: pool_expand: Assertion `0 && "Attempt to allocate an unusually large memory. The memory management does not seem to be working as intended. Please create an issue on https://github.com/OpenModelica/OpenModelica/issues."` failed. Segmentation fault (core dumped)