(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_DHC_Loads_BaseClasses_Examples_CouplingSpawnZ1_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=604800 --stepSize=241.92 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_DHC_Loads_BaseClasses_Examples_CouplingSpawnZ1_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1 (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 604800.000000 - tolerance : 1e-06 - stepSize : 241.92 warning: [fmi2Warning] CouplingSpawnZ1/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x) not in the resources directory. The FMU might not work as expected if you send it to a different system warning: [fmi2Warning] CouplingSpawnZ1/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x) not in the resources directory. The FMU might not work as expected if you send it to a different system warning: [fmi2Warning] CouplingSpawnZ1/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x) not in the resources directory. The FMU might not work as expected if you send it to a different system EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.14 12:27 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Warming up {12} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD info: Result file: Buildings_13_Buildings_DHC_Loads_BaseClasses_Examples_CouplingSpawnZ1_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable CouplingSpawnZ1.bui.building.epwName will not be stored in the result file, because the signal type is not supported info: Variable CouplingSpawnZ1.bui.building.idfName will not be stored in the result file, because the signal type is not supported info: Variable CouplingSpawnZ1.bui.building.weaName will not be stored in the result file, because the signal type is not supported info: Parameter CouplingSpawnZ1.bui.epwName will not be stored in the result file, because the signal type is not supported info: Parameter CouplingSpawnZ1.bui.idfName will not be stored in the result file, because the signal type is not supported info: Parameter CouplingSpawnZ1.bui.weaName will not be stored in the result file, because the signal type is not supported info: Parameter CouplingSpawnZ1.bui.zon.zoneName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_13_Buildings.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1/809.fmutmp/sources/Buildings_13_Buildings_DHC_Loads_BaseClasses_Examples_CouplingSpawnZ1_functions.c:5132: Invalid root: (-0.457946)^(-1.5) error: [fmi2logger] [fmi2Fatal] CouplingSpawnZ1/logStatusFatal: fmi2DoStep: ##CVODE## -8 error occurred at time = 306512.640000003. error: [fmi2logger] [fmi2Fatal] CouplingSpawnZ1/logStatusFatal: fmi2DoStep: CVODE integrator step failed. error: [stepUntil] fmi2_doStep failed for FMU "CouplingSpawnZ1.root.CouplingSpawnZ1" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error terminate called without an active exception Aborted (core dumped)