(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_12_Buildings.DHC.ETS.Combined.Examples.ChillerOnly_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_Buildings_12_Buildings_DHC_ETS_Combined_Examples_ChillerOnly_OMSimulator-cs-cvode_fmu --startTime=6.5e+06 --stopTime=7e+06 --stepSize=200 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_12_Buildings_DHC_ETS_Combined_Examples_ChillerOnly_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.DHC.ETS.Combined.Examples.ChillerOnly (co-simulation) - fmiVersion: 2.0 - startTime : 6500000.000000 - stopTime : 7000000.000000 - tolerance : 1e-06 - stepSize : 200 warning: [fmi2Warning] ChillerOnly/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" warning: [fmi2Warning] ChillerOnly/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x) not in the resources directory. The FMU might not work as expected if you send it to a different system warning: [fmi2Warning] ChillerOnly/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x) not in the resources directory. The FMU might not work as expected if you send it to a different system info: Result file: ../Buildings_12_Buildings.DHC.ETS.Combined.Examples.ChillerOnly_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter ChillerOnly.TDisWatSup.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter ChillerOnly.TDisWatSup.fileName will not be stored in the result file, because the signal type is not supported info: Parameter ChillerOnly.TDisWatSup.tableName will not be stored in the result file, because the signal type is not supported info: Parameter ChillerOnly.filNam will not be stored in the result file, because the signal type is not supported info: Parameter ChillerOnly.loa.delimiter will not be stored in the result file, because the signal type is not supported info: Variable ChillerOnly.loa.fileName will not be stored in the result file, because the signal type is not supported info: Parameter ChillerOnly.loa.tableName will not be stored in the result file, because the signal type is not supported info: 3 warnings info: 0 errors