(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_12_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctMixConInletSensor.Validation.Controller_OMSimulator-cs-cvode_res.mat --stripRoot --tempDir=temp_Buildings_12_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctMixConInletSensor_Validation_Controller_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --mode=cs --timeout=240 --tolerance=1e-06 ../Buildings_12_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctMixConInletSensor_Validation_Controller_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctMixConInletSensor.Validation.Controller (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-06 - stepSize : 34.56 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not duaDucCon.ala.truDel5.y)) --> "Warning: the hot-duct damper is leaking." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not duaDucCon.ala.truDel3.y)) --> "Warning: the cold-duct damper is leaking." info: Result file: ../Buildings_12_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctMixConInletSensor.Validation.Controller_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Variable Controller.duaDucCon.ala.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable Controller.duaDucCon.ala.assMes1.message will not be stored in the result file, because the signal type is not supported info: Variable Controller.duaDucCon.ala.assMes2.message will not be stored in the result file, because the signal type is not supported info: Variable Controller.duaDucCon.ala.assMes3.message will not be stored in the result file, because the signal type is not supported info: Variable Controller.duaDucCon.ala.assMes4.message will not be stored in the result file, because the signal type is not supported info: Variable Controller.duaDucCon.ala.assMes5.message will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 12096.000000 | | | | ((not duaDucCon.ala.truDel4.y)) --> "Warning: hot-duct airflow sensor should be calibrated." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 12096.000000 | | | | ((not duaDucCon.ala.truDel2.y)) --> "Warning: cold-duct airflow sensor should be calibrated."