(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_SingleCollectorTest_OMSimulator-cs-cvode_fmu --startTime=1.0368e+07 --stopTime=1.07136e+07 --stepSize=138.24 --mode=cs --timeout=240 --tolerance=1e-06 ../BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_SingleCollectorTest_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : BuildingSystems.Technologies.SolarThermal.Examples.SingleCollectorTest (co-simulation) - fmiVersion: 2.0 - startTime : 10368000.000000 - stopTime : 10713600.000000 - tolerance : 1e-06 - stepSize : 138.24 LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmp87wal8k8/SingleCollectorTest-mv72ztj5/temp/0001_SingleCollectorTest/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/weather/Germany_Berlin.txt" info: Result file: BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_SingleCollectorTest_OMSimulator-cs-cvode_res.mat (bufferSize=10) info: Parameter SingleCollectorTest.weatherData.weatherData.datRea.delimiter will not be stored in the result file, because the signal type is not supported info: Variable SingleCollectorTest.weatherData.weatherData.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable SingleCollectorTest.weatherData.weatherData.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter SingleCollectorTest.weatherData.weatherData.info will not be stored in the result file, because the signal type is not supported info: Variable SingleCollectorTest.weatherData.weatherData.tabNam will not be stored in the result file, because the signal type is not supported