(cd run_OMSimulator-cs-cvode && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_BuildingSystems_BuildingSystems_Applications_AirConditioningSystems_PhotovoltaicCoolingSystem_OMSimulator-cs-cvode_fmu --startTime=0 --stopTime=3.1536e+07 --stepSize=12614.4 --mode=cs --timeout=450 --tolerance=1e-06 ../BuildingSystems_BuildingSystems_Applications_AirConditioningSystems_PhotovoltaicCoolingSystem_OMSimulator-cs-cvode.fmu) LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: *** FMU Simulation Info *** - model : BuildingSystems.Applications.AirConditioningSystems.PhotovoltaicCoolingSystem (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 31536000.000000 - tolerance : 1e-06 - stepSize : 12614.4 LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmpa9kky6h6/PhotovoltaicCoolingSystem-ogh7b3up/temp/0001_PhotovoltaicCoolingSystem/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/weather/Brazil_Manaus.txt" LOG_ASSERT | debug | Division by zero 0.622 / x in function context LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | Division by zero 0.622 / x in function context LOG_ASSERT | debug | Division by zero 0.622 / x in function context LOG_ASSERT | debug | Division by zero 0.622 / x in function context LOG_ASSERT | debug | Solving non-linear system 862 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | error | Failed to solve the initialization problem with global homotopy with equidistant step size. LOG_ASSERT | debug | Unable to solve initialization problem. error: [fmi2logger] [fmi2Error] PhotovoltaicCoolingSystem/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_exitInitializationMode failed for FMU "PhotovoltaicCoolingSystem.root.PhotovoltaicCoolingSystem" error: [initialize] Initialization of system "PhotovoltaicCoolingSystem.root" failed Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 175, in _runFMU fmu.initialize() ~~~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 887, in initialize raise RuntimeError(f"Failed to initialize model: {status}") RuntimeError: Failed to initialize model: Status.error info: 0 warnings info: 3 errors